Connector Installation (Special Flat Cable Only) Section 3-2<br />

58<br />

7. Position Cover 2 onto Surface 2 of the contact block (the side without the<br />

cable stop). Always align the cables so that the main cable’s colors match<br />

the branch cable’s colors.<br />

Cover 1<br />

Main cable Cover 2<br />

Main cable<br />

Contact block<br />

Branch cable<br />

Make sure that the colors of the cables match.<br />

Branch cable<br />

Inser t until the end of the branch cable is visible.<br />

!Caution The Units could be damaged if the branch cable’s colors do not match the<br />

main cable’s colors.<br />

8. The branch cable must be inserted all the way to the contact block’s cable<br />

stop.<br />

9. Use a tool such as pliers to compress Cover 1 and Cover 2 together.<br />

!Caution Always align the tool with the centers of the Covers to prevent any bending or<br />

distortion when the connector is compressed. Uneven compression can prevent<br />

proper communications.