CQM1-SRM21-V1 Master Unit for CQM1 PLCs Section 4-4<br />

130<br />

Setting PLC word<br />

allocation<br />

The following table shows all of the possible combinations of DIP switch settings.<br />

Max. number of<br />

I/O points<br />

Points/n<br />

ode<br />

number<br />

Note When the CQM1 Master Unit is used in 4-point mode, Slaves with 16 points or<br />

more cannot be used. If Slaves with 16 points or more are used, a data area<br />

overlap error (ERS indicator lit) will occur.<br />

Set the communications mode with DIP switch pin 4 (DR), as shown in the following<br />

table.<br />

Note 1. Make sure that the communications mode of the Master Unit is the same<br />

as that of all the Slaves. If the <strong>CompoBus</strong>/S System contains a Slave with<br />

a different communications mode, the COMM indicator on that Slave will<br />

not light, and normal communications with that Slave will not be possible.<br />

Other Slaves will not be adversely affected, and the COMM indicator on the<br />

Master Unit will light normally. For information relating to the states of the<br />

Master Unit indicator, refer to 6-5-1 Indicators.<br />

2. When using a previous Master Unit model (without V1), pin 4 must be set<br />

to OFF. Otherwise, normal communications may not be possible.<br />

3. Pin 4 is factory-set to OFF (High-speed Communications Mode).<br />

4. The settings for the communications distance, baud rate, and communications<br />

cycle time vary according to the setting of pin 4, as shown in the<br />

above table.<br />

4-4-3 I/O Allocations in CQM1 PLCs<br />

Usable node<br />

numbers<br />

Pin 1 Pin 2 Pin 3 HighspeedCommunications<br />

Mode<br />

OFF OFF OFF 2 words<br />

(1 IN/1 OUT)<br />

ON OFF OFF 4 words<br />

(2 IN/2 OUT)<br />

OFF ON OFF 8 words<br />

(4 IN/4 OUT)<br />

ON ON OFF<br />

OFF OFF ON 2 words<br />

(1 IN/1 OUT)<br />

ON OFF ON 4 words<br />

(2 IN/2 OUT)<br />

OFF ON ON 8 words<br />

ON ON ON (4 IN/4 OUT)<br />

16 input points,<br />

16 output points<br />

32 input points,<br />

32 output points<br />

64 input points,<br />

64 output points<br />

16 input points,<br />

16 output points<br />

32 input points,<br />

32 output points<br />

64 input points,<br />

64 output points<br />

Pin 4 Communications<br />

mode setting<br />

OFF High-speed Communications<br />

Mode<br />

ON Long-distance<br />

Communications<br />

Mode<br />

8 points IN: 0 and 1<br />

OUT: 0 and 1<br />

8 points IN: 0 to 3<br />

OUT: 0 to 3<br />

8 points IN: 0 to 7<br />

OUT: 0 to 7<br />

4 points IN: 0 to 3<br />

OUT: 0 to 3<br />

4 points IN: 0 to 7<br />

OUT: 0 to 7<br />

4 points IN: 0 to 15<br />

OUT: 0 to 15<br />

Communications<br />

distance<br />

Communications cycle<br />

time<br />

Long-distanceCommunications<br />

Mode<br />

Use of AnalogTerminals<br />

0.5 ms 4.0 ms Possible<br />

(Only for<br />

0.5 ms 4.0 ms Master Unit<br />

models with-<br />

0.5 ms 4.0 ms<br />

V1. Not possible<br />

for<br />

models without<br />

V1.)<br />

0.5 ms 4.0 ms Not possible<br />

0.5 ms 4.0 ms<br />

0.8 ms 6.0 ms<br />

Communications<br />

baud rate<br />

Communications<br />

cycle time<br />

100 m max. 750 kbps 0.5 or 0.8 ms<br />

500 m max. 93.75 kbps 4.0 or 6.0 ms<br />

In CQM1 PLCs, the Master Unit is treated just like an I/O Unit that has both<br />

inputs and outputs, so the Slave’s I/O data is stored in the words allocated to<br />

those inputs and outputs.