Checking Operations for CS-series, C200HX/C200HG/C200HE-(Z)E, and C200HS Master Units Section 6-2<br />

6-2-4 Troubleshooting<br />

360<br />

Wrong<br />

Correct<br />

(n + 4 words bit 00)<br />

Input Slave<br />

Bit 00 of node number 0<br />

<strong>CompoBus</strong>/S Master Unit<br />

The system is not always in normal operation<br />

when bit 00 of input Slave 0 is turned ON.<br />

Normal operation<br />

Normal communications<br />

Slave<br />

Bit 00 ON<br />

Bit 10400 is ON<br />

and the system<br />

seems to be in<br />

normal operation.<br />

Communications<br />

error<br />

10900<br />

(n + 9 words bit 00)<br />

10908<br />

(n + 9 words bit 08)<br />

AR bit<br />

Work bit (a) is ON if input Slave Node 0 is<br />

Input Slave<br />

Node address 0<br />

Active Node Flag<br />

in normal communication in the network.<br />

Input Slave<br />

Node address 0 Normal operation<br />

Communications Error Flag<br />

a<br />

10400<br />

(n + 4 words bit 00)<br />

Input Slave<br />

Node address 0<br />

Bit 00<br />

Communications error<br />

<strong>CompoBus</strong>/S<br />

Master Unit<br />

Bit 00 of input Slave is used after checking<br />

that the system is in normal operation.<br />

Bit 10400 is<br />

ON and the<br />

system seems<br />

to be in normal<br />

operation.<br />

It is possible to write a ladder program that confirms normal operation when a<br />

work bit (a) turns OFF.<br />

A ladder program that checks all the Active Node Flags and Communications<br />

Error Flags in a batch, checks the overall <strong>CompoBus</strong>/S System operations,<br />

and then performs I/O processing for the Slaves in a batch can also be written.<br />

For details, refer to the section for CJ-series Master Units under 6-3-4<br />

Checking Normal Operations Using Ladder Programming.<br />

When an error occurs, the indicators of a Master Unit connected to a CSseries,<br />

C2missing00HX/C200HG/C200HE-(Z)E, or C200HS PLC will indicate<br />

the error. Check the Master Unit’s indicators and perform the error processing<br />

described in the following table.<br />

Slave<br />

Bit 00 is OFF when a<br />

communications error<br />

occurs.