Compatible Devices Section 1-3<br />

Cables <strong>CompoBus</strong>/S communications are transmitted through Special Flat Cable or<br />

4-conductor VCTF cable. The communications power supply can be supplied<br />

through either of the cables.<br />

Connection Methods Two methods can be used to connect the <strong>CompoBus</strong>/S Master and Slaves:<br />

the T-branch method and the multidrop method. With the T-branch method,<br />

the Slave is connected to a line that branches off from the communications<br />

cable wherever desired. With the multidrop method, the Master or Slave is<br />

connected directly to the communications cable. These two connection methods<br />

can both be used in the same system and it is possible to make a secondary<br />

branch from a branch line. Use OMRON’s Branch Connector for Special<br />

Flat Cable, a T-joint for a shielded connector, or a commercially available terminal<br />

block to create a branch from the communications cable.<br />

Terminator A terminator must be connected to the end of the communications cable farthest<br />

from the Master in order to stabilize communications. There are three<br />

kinds of terminating resistors available, a connector for use with Special Flat<br />

Cable, a terminal block, and a shielded connector. In a system in which distinguishing<br />

between the main and branch lines is not necessary, only a single<br />

terminator farthest from the Master is required regardless of the position the<br />

Master is connected to the communications cable.<br />

1-3 Compatible Devices<br />

1-3-1 Compatible Masters<br />

Masters with<br />

Communications<br />

Functions<br />

10<br />

PLC C200HX-CPU3@-<br />

(Z)E/ CPU4@-(Z)E,<br />

C200HG-CPU3@-<br />

(Z)E/CPU4@-(Z)E,<br />

C200HE, C200HS<br />

Master<br />

Unit<br />

Communications<br />

mode<br />

Analog I/O<br />

Terminal<br />

connection<br />

Max. number<br />

of Masters<br />

Master<br />

Unit<br />

mounting<br />

location<br />

There are three types of Master Units which can be used in <strong>CompoBus</strong>/S<br />

Systems. The model of the Master Unit which must be used depends on the<br />

PLC being used.<br />

C200HX-CPU5@-<br />

(Z)E/ CPU6@-(Z)E/<br />

CPU8@-(Z)E,<br />

C200HG-CPU5@-<br />

(Z)E/ CPU6@-(Z)E,<br />

CS Series<br />

CS Series CJ Series CQM1, CQM1H<br />

C200HW-SRM21-V1 CS1W-SRM21 CJ1W-SRM21 CQM1-SRM21-V1<br />

High-speed Communications Mode or Long-distance Communications Mode (switched using the DIP switch<br />

on front panel)<br />

Possible<br />

10 Units (when<br />

using a single Special<br />

I/O Unit node<br />

number (i.e., 10<br />

words))<br />

5 Units (when using<br />

two Special I/O Unit<br />

node number (i.e.,<br />

20 words))<br />

16 Units (when<br />

using a single Special<br />

I/O Unit node<br />

number (i.e., 10<br />

words))<br />

8 Units (when using<br />

two Special I/O Unit<br />

node number (i.e.,<br />

20 words))<br />

96 Units (when<br />

using a single Special<br />

I/O Unit node<br />

number (i.e., 10<br />

words))<br />

95 Units (when<br />

using two Special<br />

I/O Unit node number<br />

(i.e., 20 words))<br />

Can be mounted on the CPU Backplane or Expansion I/O Backplane.<br />

Can’t be mounted on a SYSMAC BUS Slave (RT) Rack.<br />

40 Units CQM1: 1 Unit<br />

CQM1H: Up to the<br />

number corresponding<br />

to the maximum<br />

I/O points for the<br />

CPU Unit.<br />

Can be connected<br />

in the CPU Rack or<br />

Expansion Rack.<br />

No restrictions.