Hardware Installation, Deinstallation and Replacement 115/274<br />

Connecting the AIFX-DIAG<br />

6. If so, connect the assembly interface diagnostic (AIFX-DIAG):<br />

‣ Connect the cable connector DIAG X1 on the AIFX-DIAG with the<br />

cable.<br />

Important! The contacts on the connection cable must face up!<br />

<br />

Figure 27: Connect the cable connector DIAG X1 on the AIFX-DIAG with the cable.<br />

‣ Connect the cable connector DIAG X3 (or X303) on the CIFX 104C-<br />

RE\F <strong>Communication</strong> Interface with the cable.<br />

Important! The contacts on the connection cable must face up!<br />

<br />

Figure 28: Connect the cable connector DIAG X303 on the CIFX 104C-RE\F* with the cable.<br />

(*Example in this figure)<br />

‣ Install the AIFX-DIAG on the front plate of the CIFX 104C-RE\F.<br />

For more see next page.<br />

<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />

DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011