cifX Communication Interfaces Real-Time Ethernet - Hilscher
cifX Communication Interfaces Real-Time Ethernet - Hilscher
cifX Communication Interfaces Real-Time Ethernet - Hilscher
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Technical Data 238/274<br />
10 Technical Data<br />
10.1 Technical Data <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Real</strong>-<strong>Time</strong><br />
<strong>Ethernet</strong><br />
Note: All technical data are temporarily and can be altered without notice.<br />
10.1.1 CIFX 50-RE<br />
Item<br />
System Interface<br />
(Bus Type)<br />
Dual-Port Memory Size<br />
Function<br />
<strong>Communication</strong><br />
Protocols<br />
<strong>Ethernet</strong> Frame Types<br />
CIFX 50-RE<br />
PCI, according to [bus spec 1], refer to section Overview on the Pin<br />
Assignment at the Bus, page 230,<br />
32-Bit width for the data access to the Dual-Port Memory (DPM), or DMA<br />
(Direct Memory Access)<br />
64 KBytes<br />
<strong>Communication</strong> interface with PCI and <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> interface<br />
Determined by the loaded firmware<br />
EtherCAT Master, EtherCAT Slave,<br />
EtherNet/IP-Scanner (Master), EtherNet/IP-Adapter (Slave), Open<br />
Modbus/TCP,<br />
Powerlink Controlled Node/Slave,<br />
PROFINET IO-Controller, PROFINET IO-Device,<br />
SERCOS III Master, SERCOS III Slave<br />
<strong>Ethernet</strong> II<br />
Processor netX 500<br />
LEDs<br />
SYS, COM 0, COM 1, 2x Link, 2x Activity;<br />
refer also to chapter LED Descriptions, page 200.<br />
Rotary Switch Slot Number (Card ID)* To set the Slot Number (Card ID);<br />
(*provided from hardware revision 3 on)<br />
Configuration Software<br />
SYCON.net<br />
<strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> Master<br />
Configuration Software<br />
netX Configuration Tool or SYCON.net<br />
<strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> Slave<br />
Transmission Rate 10/100 MBit/s, Auto-Negotiation, Auto-Cross-Over, Halfduplex/Fullduplex (100<br />
MBit/s)<br />
Depending on used firmware<br />
<strong>Ethernet</strong> Interface<br />
RJ45 Socket, 10 Base-T, 100 Base-TX, potential free;<br />
refer also to section <strong>Ethernet</strong> Interface, page 219.<br />
Supply Voltage<br />
+3.3 V dc ±5 %/Typ. 650 mA<br />
Dimensions (L x W x D) Beginning with hardware revision 3:<br />
120,0 x 86 x 18,5 mm; [B = 86 mm, as with Rotary Switch Slot Number (Card<br />
ID)].<br />
Up to and including hardware revision 2:<br />
120,0 x 73,2 x 18,5 mm; [B = 73,2 mm, as without Rotary Switch Slot Number<br />
(Card ID)].<br />
Operating Temperature -20 °C ... +55 °C<br />
Environment<br />
The device must be used in a pollution degree 2 environment.<br />
UL Certification<br />
The device is UL 508 certified (UL-File No E221530).<br />
Table 86: Technical Data CIFX 50-RE<br />
<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />
DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011