Descriptions and Requirements 46/274<br />

3.3 Requirements for Operation<br />

3.3.1 AIFX-RE must be connected<br />

Important! Pre-requirement for the operation of the <strong>cifX</strong> <strong>Communication</strong><br />

<strong>Interfaces</strong> with Cable Connector <strong>Ethernet</strong> (label “\F” in its device name)<br />

is, that the assembly interface <strong>Ethernet</strong> (AIFX-RE) is connected!<br />

<strong>cifX</strong> with Cable Connector <strong>Ethernet</strong> Assembly Interface <strong>Ethernet</strong><br />

(label „\F“)<br />

CIFX 90-RE\F<br />

AIFX-RE<br />

CIFX 90E-RE\F<br />

CIFX 104C-RE\F<br />

CIFX 104C-RE-R\F<br />

CIFX 104-RE\F<br />

CIFX 104-RE-R\F<br />

Table 22: <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> with Label „\F“ and corresponding Assembly<br />

Interface <strong>Ethernet</strong> (AIFX-RE)<br />

3.3.2 <strong>cifX</strong> Device Driver<br />

Note: Upgrade older versions of the <strong>cifX</strong> Device Driver necessarily on<br />

the version V1.0.x.x.<br />

3.3.3 <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> (Slave)<br />

For <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> (Slave) to operate<br />

properly, the following requirements must be fulfilled:<br />

Protocols<br />

Software<br />

Installation<br />

Firmware-<br />

Download<br />

Parameter Setting<br />

<strong>Communication</strong><br />

EtherCAT Slave,<br />

EtherNet/IP-Adapter (Slave),<br />

Open Modbus/TCP,<br />

Powerlink Controlled Node/Slave,<br />

PROFINET IO-Device,<br />

SERCOS III Slave<br />

1. The <strong>cifX</strong> Device Driver must be installed (from V1.0.x.x).<br />

2. The netX Configuration Tool program must be installed or<br />

alternatively the configuration software SYCON.net or another<br />

application program by which the <strong>cifX</strong> <strong>Communication</strong> Interface <strong>Real</strong>-<br />

<strong>Time</strong> <strong>Ethernet</strong> (Slave) can be parameterized.<br />

3. Using the netX Configuration Tool program, the user must select<br />

the firmware which is to be loaded to the <strong>cifX</strong> <strong>Communication</strong><br />

Interface <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> (Slave).<br />

4. The <strong>cifX</strong> <strong>Communication</strong> Interface <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> (Slave)<br />

must be parameterized using one of the following options:<br />

• netX Configuration Tool program<br />

• Application program (programming required)<br />

5. For the communication a Master for the respective communication<br />

system is required.<br />

Table 23: Requirements for Operation of <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong><br />

(Slave)<br />

<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />

DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011