Descriptions and Requirements 46/274<br />
3.3 Requirements for Operation<br />
3.3.1 AIFX-RE must be connected<br />
Important! Pre-requirement for the operation of the <strong>cifX</strong> <strong>Communication</strong><br />
<strong>Interfaces</strong> with Cable Connector <strong>Ethernet</strong> (label “\F” in its device name)<br />
is, that the assembly interface <strong>Ethernet</strong> (AIFX-RE) is connected!<br />
<strong>cifX</strong> with Cable Connector <strong>Ethernet</strong> Assembly Interface <strong>Ethernet</strong><br />
(label „\F“)<br />
CIFX 90-RE\F<br />
AIFX-RE<br />
CIFX 90E-RE\F<br />
CIFX 104C-RE\F<br />
CIFX 104C-RE-R\F<br />
CIFX 104-RE\F<br />
CIFX 104-RE-R\F<br />
Table 22: <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> with Label „\F“ and corresponding Assembly<br />
Interface <strong>Ethernet</strong> (AIFX-RE)<br />
3.3.2 <strong>cifX</strong> Device Driver<br />
Note: Upgrade older versions of the <strong>cifX</strong> Device Driver necessarily on<br />
the version V1.0.x.x.<br />
3.3.3 <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> (Slave)<br />
For <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> (Slave) to operate<br />
properly, the following requirements must be fulfilled:<br />
Protocols<br />
Software<br />
Installation<br />
Firmware-<br />
Download<br />
Parameter Setting<br />
<strong>Communication</strong><br />
EtherCAT Slave,<br />
EtherNet/IP-Adapter (Slave),<br />
Open Modbus/TCP,<br />
Powerlink Controlled Node/Slave,<br />
PROFINET IO-Device,<br />
SERCOS III Slave<br />
1. The <strong>cifX</strong> Device Driver must be installed (from V1.0.x.x).<br />
2. The netX Configuration Tool program must be installed or<br />
alternatively the configuration software SYCON.net or another<br />
application program by which the <strong>cifX</strong> <strong>Communication</strong> Interface <strong>Real</strong>-<br />
<strong>Time</strong> <strong>Ethernet</strong> (Slave) can be parameterized.<br />
3. Using the netX Configuration Tool program, the user must select<br />
the firmware which is to be loaded to the <strong>cifX</strong> <strong>Communication</strong><br />
Interface <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> (Slave).<br />
4. The <strong>cifX</strong> <strong>Communication</strong> Interface <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> (Slave)<br />
must be parameterized using one of the following options:<br />
• netX Configuration Tool program<br />
• Application program (programming required)<br />
5. For the communication a Master for the respective communication<br />
system is required.<br />
Table 23: Requirements for Operation of <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong><br />
(Slave)<br />
<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />
DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011