Hardware Installation, Deinstallation and Replacement 75/274<br />

5.4.7 Replacing CIFX 50-RE and CIFX 50E-RE<br />

To replace the<br />

• CIFX 50-RE <strong>Communication</strong> Interface PCI and the<br />

• CIFX 50E-RE <strong>Communication</strong> Interface PCI Express<br />

handle as follows:<br />

1. Fix front plate sticker.<br />

‣ Use the sticker according to the firmware and glue it on the front of the<br />

replacement CIFX 50-RE or CIFX 50E-RE (see section Fix Front Plate<br />

Sticker at CIFX 50-RE and CIFX 50E-RE on page 71).<br />

2. If so, set Slot Number (Card ID).<br />

Important! For replacement CIFX 50-RE or CIFX 50E-RE with Rotary<br />

Switch Slot Number (Card ID) set the same Slot Number (Card ID) as<br />

at the previous <strong>cifX</strong> (see section PCI and PCI Express: Setting Slot<br />

Number (Card ID) on page 67).<br />

Device revisions equipped with a Rotary Switch Slot Number (Card ID)<br />

are listed separately in section Hardware: <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong><br />

<strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> in Table 2 on page 17.<br />

3. Take safety precautions.<br />

Lethal Electrical Shock caused by parts with more than 50V!<br />

• Disconnect the power plug of the PC or of the connecting device.<br />

• Make sure, that the power supply is off at the PC or at the connecting<br />

device.<br />

4. Remove the connecting cable to the Master or Slave.<br />

‣ Remove the connecting cable between the CIFX 50-RE or CIFX 50E-<br />

RE <strong>Communication</strong> Interface to be replaced and the PC card <strong>Real</strong>-<strong>Time</strong><br />

<strong>Ethernet</strong> Master or Slave.<br />

5. Open cabinet.<br />

‣ Open the cabinet of the PC or of the connecting device.<br />

6. Deinstall CIFX 50-RE <strong>Communication</strong> Interface PCI.<br />

‣ Loosen the CIFX 50-RE.<br />

‣ Remove the CIFX 50-RE from the PCI slot.<br />

7. Install replacement CIFX 50-RE.<br />

‣ Plug the replacement CIFX 50-RE into the vacated PCI slot.<br />

‣ Fix the replacement CIFX 50-RE using the hole intended.<br />

For more see next page.<br />