Device Connections and Switches 228/274<br />

9.9 SYNC Connector (Pin-Assignment, Hardware/Firmware)<br />

9.9.1 Pin Assignment SYNC Connector, X51<br />

Only for:<br />

CIFX 50-RE (since hardware Rev. 3), CIFX 50E-RE,<br />

CIFX 80-RE, CIFX 90-RE\F,<br />

CIFX 104C-RE, CIFX 104C-RE-R, CIFX 104C-RE\F, CIFX 104C-RE-R\F,<br />

CIFX 104-RE, CIFX 104-RE-R, CIFX 104-RE\F, CIFX 104-RE-R\F.<br />

Pin<br />

Signal<br />

1 GND<br />

2 IO_SYNC0<br />

3 IO_SYNC1<br />

Table 74: Pin Assignment for SYNC Connector, X51<br />

CIFX 90E-RE\F: The SYNC pins are on the Mini PCI Express port (Pin 46,<br />

44), refer to section Pin Assignment for Mini PCI Express Bus / SYNC<br />

Connector (Bootstart), X1/X2, on page 233.<br />

9.9.2 Pin Assignment SYNC Connector, J3<br />

Only for: CIFX 100EH-RE\CUBE.<br />

Pin Signal<br />

1 IO_SYNC0<br />

2 Jumper set: SYNC signal is transferred to the PCI-Express Bus Pin B24*<br />

Jumper not set: static high 3,3 V (with pull-up)<br />

3 IO_SYNC1<br />

Table 75: Pin Assignment for SYNC Connector, J3<br />

Note! *<br />

• If the jumper is set on Pin1-Pin2, the IO_SYNC0 signal is transferred to<br />

the PCI Express Bus X2 (pin B24).<br />

Or<br />

• If the jumper is set on Pin2-Pin3, the IO_SYNC1 signal is transferred to<br />

the PCI Express Bus X2 (pin B24).<br />

Or<br />

• If the no jumper is set, the signal at the PCI Express Bus X2 pin B24 is<br />

static High 3,3 V (with pull-up).<br />

Compare section Pin Assignment for PCI Express Bus CIFX 100EH-<br />

RE\CUBE on page 235.<br />

<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />

DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011