Hardware Installation, Deinstallation and Replacement 135/274<br />

5.12.3 Installing CIFX 104-RE\F and CIFX 104-RE-R\F<br />

To install the<br />

• CIFX 104-RE\F <strong>Communication</strong> Interface PC/104(„\F“) and<br />

• CIFX 104-RE-R\F <strong>Communication</strong> Interface PC/104(„\F“)<br />

handle as follows:<br />

1. Configure starting address, interrupt and data bus width of the CIFX<br />

104-RE\F <strong>Communication</strong> Interface.<br />

‣ Configure the start address of the CIFX 104-RE\F.<br />

‣ If you are using the interrupt mode, set up a free interrupt on the CIFX<br />

104-RE\F.<br />

For polling operation mode interrupt jumpers are not required.<br />

Note: Several CIFX 104-RE\F <strong>Communication</strong> <strong>Interfaces</strong> can be plugged<br />

as modules one upon the other. For each CIFX 104-RE\F <strong>Communication</strong><br />

Interface you must define a free memory area of 16 KByte.<br />

For further information on the starting address and or an interrupt (or<br />

polling) refer to section <strong>cifX</strong> PC/104: Set Starting Address and Interrupt on<br />

page 124.<br />

‣ Depending by the target system (motherboard), if so, set at the CIFX<br />

104-RE\F a Data Bus Width of 8 bit or 16 bit.<br />

By default the jumper is set for a data bus width of 16 Bit (refer to section<br />

Device Drawing CIFX 104-RE\F on page 133 and Device Drawing CIFX<br />

104-RE-R\F on page 134).<br />

2. Take safety precautions.<br />

Lethal Electrical Shock caused by parts with more than 50V!<br />

• Disconnect the power plug of the PC or of the connecting device.<br />

• Make sure, that the power supply is off at the PC or at the connecting<br />

device.<br />

3. Open cabinet.<br />

‣ Open the cabinet of the PC or of the connecting device.<br />

Note: If several CIFX 104-RE\F <strong>Communication</strong> <strong>Interfaces</strong> are to be put<br />

together as modules in a stack:<br />

(a) Install the first <strong>cifX</strong> on the mainboard.<br />

(b) Connect the AIFX-RE or the AIFX-DIAG to the <strong>cifX</strong>.<br />

(e) Connect any other module in the same way (as a and b).<br />