Device Connections and Switches 227/274<br />

9.8.2 Pin Assignment for Cable Connector DIAG<br />

Only for:<br />

CIFX 104C-RE\F (X303), CIFX 104C-RE-R\F (X3),<br />

CIFX 104-RE\F (X3), CIFX 104-RE-R\F (X303).<br />

Pin Assignment for Cable connector DIAG X3 or X303 - Cable 12 pin USB<br />

+ Status LEDs<br />

Pin<br />

Signal<br />

1 GND<br />

2 +3V3<br />

3 STA2 (not used)<br />

4 STA3 (not used)<br />

5 USB_POS<br />

6 USB_NEG<br />

7 RDYn<br />

8 RUNn<br />

9 STA0_green (RE LED COM 0)<br />

10 STA0_red (RE LED COM 0)<br />

11 STA1_green (RE LED COM 1)<br />

12 STA1_red (RE LED COM 1)<br />

Table 73: Pin Assignment for Cable connector DIAG X3 or X303<br />

<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />

DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011