Hardware Installation, Deinstallation and Replacement 126/274<br />

5.11 <strong>cifX</strong> <strong>Communication</strong> Interface PC/104<br />

5.11.1 Device Drawing CIFX 104-RE<br />

Note:<br />

Note:<br />

Device supports Auto Crossover Function<br />

With loaded EtherCAT Master firmware only RJ-45 channel 0 can be used, channel 1 is deactivated. For<br />

Open Modbus/TCP with V2.3.4.0 and higher both channels can be used.<br />

Figure 35: Device Drawing CIFX 104-RE<br />

The meaning of the LEDs displayed in Figure 35 depends from the loaded<br />

firmware. See chapter LED Descriptions beginning from page 200.<br />

Further refer to Device Connections and Switches page 215:<br />

For the pin assignment of the PCI/104 bus X1/X2 displayed in Figure 35<br />

refer to section Pin Assignment for PC/104 Bus on page 236.<br />

For the SYNC pin assignment of the SYNC Connector displayed in Figure<br />

35 refer to section Pin Assignment SYNC Connector, X51 on page 228.<br />

For further information on the Mini-B USB Connector displayed in Figure<br />

35 refer to section Mini-B USB Connector (5 Pin) on page 221.<br />

<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />

DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011