Getting Started <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> 59/274<br />

4.6.2 Steps how to replace the Hardware<br />

The following table describes the steps on how to replace a <strong>cifX</strong><br />

<strong>Communication</strong> Interface <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> (Master and Slave) with and<br />

without Rotary Switch Slot Number (Card ID) as it is typical for many<br />

cases.<br />

# Step Description For detailed information<br />

see section<br />

1 Preparation<br />

Glue sticker on the<br />

front plate.<br />

Set the Slot Number<br />

(Card ID)<br />

(only device with a<br />

Rotary Switch)<br />

For CIFX 50-RE and CIFX 50E-RE:<br />

For CIFX 80-RE:<br />

For CIFX 100EH-RE\CUBE:<br />

Currently only CIFX 50-RE, CIFX 50E-RE and<br />

und CIFX 100EH-RE\CUBE:<br />

Important! At the replacement <strong>cifX</strong><br />

set the same Slot Number (Card<br />

ID) as at the previous <strong>cifX</strong>.<br />

Fix Front Plate Sticker at<br />

CIFX 50-RE and CIFX<br />

50E-RE<br />

Fix Front Plate Sticker at<br />

CIFX 80-RE<br />

Fix Front Plate Sticker at<br />

CIFX 100EH-RE\CUBE<br />

PCI and PCI Express:<br />

Setting Slot Number<br />

(Card ID)<br />

Page<br />

71<br />

78<br />

96<br />

67<br />

Device revisions equipped with a Rotary<br />

Switch Slot Number (Card ID) are listed<br />

separately in Table 2.<br />

Hardware: <strong>cifX</strong><br />

<strong>Communication</strong><br />

<strong>Interfaces</strong> <strong>Real</strong>-<strong>Time</strong><br />

<strong>Ethernet</strong><br />

17<br />

Set PCI 104 Slot<br />

Number.<br />

For <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> PCI 104:<br />

Set physical PCI 104 Slot Number.<br />

Replacing CIFX 104C-RE<br />

and CIFX 104C-RE-R<br />

Replacing CIFX 104C-<br />

RE\F and CIFX 104C-RE-<br />

R\F<br />

109,<br />

119<br />

For <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> PC/104:<br />

Set Starting Address<br />

and Interrupt<br />

Set Data Bus Width.<br />

Depending by the target system<br />

(motherboard), if so, set a Data Bus Width of<br />

8 bit or 16 bit. (Default jumper setting 16 Bit)<br />

<strong>cifX</strong> PC/104: Set Starting<br />

Address and Interrupt<br />

Device Drawing CIFX<br />

104-RE,<br />

Device Drawing CIFX<br />

104-RE-R,<br />

Device Drawing CIFX<br />

104-RE\F,<br />

Device Drawing CIFX<br />

104-RE-R\F<br />

124<br />

126,<br />

127,<br />

133,<br />

134<br />

<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />

DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011