Hardware Installation, Deinstallation and Replacement 65/274<br />
5.2 Property Damage Messages<br />
Obey to the following property damage messages, when installing,<br />
deinstalling or replacing the <strong>cifX</strong> <strong>Communication</strong> Interface.<br />
5.2.1 Device Destruction by exceeding allowed Supply Voltage<br />
Adhere for all <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> described in this manual the<br />
instruction hereafter:<br />
NOTICE<br />
Device Destruction!<br />
• Use only the mandatory supply voltage to operate the <strong>cifX</strong> <strong>Communication</strong><br />
Interface.<br />
• Operating the <strong>cifX</strong> with a supply voltage above of the specified range<br />
leads to device destruction.<br />
USA:<br />
Device Destruction!<br />
• Use only the mandatory supply voltage to operate the <strong>cifX</strong> <strong>Communication</strong><br />
Interface.<br />
• Operating the <strong>cifX</strong> with a supply voltage above of the specified range<br />
leads to device destruction.<br />
5.2.2 Device Destruction by exceeding allowed Signaling Voltage<br />
Adhere for all <strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> described in this manual the<br />
instruction hereafter:<br />
NOTICE<br />
Device Destruction!<br />
• All I/O signal pins at the <strong>cifX</strong> <strong>Communication</strong> Interface tolerate only a<br />
specified signaling voltage!<br />
• Operation with a signaling voltage other than the specified signaling<br />
voltage may lead to severe damage to the <strong>cifX</strong> <strong>Communication</strong><br />
Interface!<br />
For detailed information on the supply and signaling voltage of the <strong>cifX</strong><br />
<strong>Communication</strong> <strong>Interfaces</strong> described in this manual, refer to section Supply<br />
Voltage and Signal Voltage on page 44.<br />
USA:<br />
Device Destruction!<br />
• All I/O signal pins at the <strong>cifX</strong> <strong>Communication</strong> Interface tolerate only a<br />
specified signaling voltage!<br />
• Operation with a signaling voltage other than the specified signaling<br />
voltage may lead to severe damage to the <strong>cifX</strong> <strong>Communication</strong><br />
Interface!<br />
<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />
DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011