Device Connections and Switches 219/274<br />

9.3 <strong>Ethernet</strong> Interface<br />

For the <strong>Ethernet</strong> interface use RJ45 plugs and twisted pair cable of<br />

category 5 (CAT5) or higher, which consists of 4 twisted cores and has a<br />

maximum transmission rate of 100 MBit/s (CAT5).<br />

9.3.1 <strong>Ethernet</strong> Pin Assignment at the RJ45 Socket<br />

Note: The device supports the Auto Crossover function. Due to this fact<br />

RX and TX can be switched. The following figure shows the RJ45<br />

standard pin assignment.<br />

Figure 77: <strong>Ethernet</strong> Pin Assignment at the RJ45 Socket for <strong>cifX</strong> or AIFX<br />

Pin Signal Meaning<br />

1 TX+ Transmit Data +<br />

2 TX– Transmit Data –<br />

3 RX+ Receive Data +<br />

4 Term 1 Connected to each other and<br />

5 Term 1<br />

terminated to PE through RC circuit*<br />

6 RX– Receive Data –<br />

7 Term 2 Connected to each other and<br />

8 Term 2<br />

terminated to PE through RC circuit*<br />

* Bob Smith Termination<br />

Table 65: <strong>Ethernet</strong> Pin Assignment at the RJ45 Socket for <strong>cifX</strong> or AIFX<br />

Further Notes:<br />

(1) The RJ45 socket is only for use in LAN, not for telecommunication circuits.<br />

(2) With loaded EtherCAT Master firmware only the RJ-45 channel 0 can be used, the<br />

channel 1 is deactivated. For the Open Modbus/TCP firmware with V2.3.4.0 and higher<br />

both RJ-45 RJ-45channels can be used.<br />

9.3.2 <strong>Ethernet</strong> Connection Data<br />

Medium<br />

Length of cable<br />

Transmission<br />

rate<br />

Table 66: <strong>Ethernet</strong> Connection Data<br />

2 x 2 Twisted-Pair cupric cable, CAT5 (100 MBit/s)<br />

Typ. 100 m<br />

10 MBit/s/100 MBit/s<br />

<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />

DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011