11.01.2014 Views

cifX Communication Interfaces Real-Time Ethernet - Hilscher

cifX Communication Interfaces Real-Time Ethernet - Hilscher

cifX Communication Interfaces Real-Time Ethernet - Hilscher

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

LED Descriptions 203/274<br />

8.4 EtherCAT Slave<br />

The subsequent table describes the meaning of the LEDs for the <strong>cifX</strong><br />

<strong>Communication</strong> Interface <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> Slave when the firmware of<br />

the EtherCAT Slave protocol is loaded to the device.<br />

LED Color State Meaning<br />

RUN Duo LED red/green<br />

Name in<br />

Off<br />

INIT: The device is in state INIT<br />

(off)<br />

the<br />

device<br />

Blinking PRE-OPERATIONAL: The device is in state PREdrawing:<br />

(green)<br />

OPERATIONAL<br />

COM 0<br />

Single Flash SAFE-OPERATIONAL: The device is in state SAFE-<br />

(green)<br />

OPERATIONAL<br />

On<br />

OPERATIONAL: The device is in state OPERATIONAL<br />

(green)<br />

ERR Duo LED red/green<br />

Off<br />

No error: The EtherCAT communication of the device is in<br />

(off)<br />

working condition<br />

Name in<br />

the<br />

device<br />

drawing:<br />

COM 1<br />

L/A IN/<br />

RJ45<br />

Ch0<br />

L/A<br />

OUT/<br />

RJ45<br />

Ch1<br />

RJ45<br />

Ch0<br />

RJ45<br />

Ch1<br />

(red) Blinking Invalid Configuration: General Configuration Error<br />

(Example: State change commanded by master is<br />

impossible due to register or object settings.)<br />

(red) Single Flash Unsolicited State Change: Slave device application has<br />

changed the EtherCAT state autonomously: Parameter<br />

"Change" in the AL status register is set to<br />

0x01:change/error<br />

(Example: Synchronization Error, device enters Safe-<br />

Operational automatically.)<br />

(red) Double Flash Application Watchdog <strong>Time</strong>out: An application watchdog<br />

timeout has occurred.<br />

(Example: Sync Manager Watchdog timeout)<br />

(red) On PDI Watchdog <strong>Time</strong>out: A PDI Watchdog timeout has<br />

occurred<br />

(Example: Application controller is not responding any more)<br />

LED green<br />

On<br />

A link is established<br />

(green)<br />

Flashing The device sends/receives <strong>Ethernet</strong> frames<br />

(green)<br />

Off<br />

No link established<br />

(off)<br />

LED yellow<br />

- -<br />

(yellow)<br />

Table 52: LEDs EtherCAT Slave<br />

<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />

DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011