LED Descriptions 202/274<br />

8.3 EtherCAT Master<br />

The subsequent table describes the meaning of the LEDs for the <strong>cifX</strong><br />

<strong>Communication</strong> Interface <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> Master when the firmware of<br />

the EtherCAT Master protocol is loaded to the device.<br />

LED Color State Meaning<br />

RUN Duo LED red/green<br />

Name in<br />

Off<br />

INIT: The device is in state INIT<br />

(off)<br />

the<br />

device<br />

Blinking PRE-OPERATIONAL: The device is in PREdrawing:<br />

(green)<br />

OPERATIONAL state<br />

COM 0<br />

Flickering BOOT: Device is in Boot mode<br />

(green)<br />

Single Flash SAFE-OPERATIONAL: The device is in SAFE-<br />

(green)<br />

OPERATIONAL state<br />

On<br />

OPERATIONAL: The device is in OPERATIONAL state<br />

(green)<br />

ERR Duo LED red/green<br />

Name in<br />

Off<br />

Master has no errors<br />

(off)<br />

the<br />

device (red) On Master has detected a communication error. The error is<br />

drawing:<br />

indicated in the DPM<br />

COM 1<br />

LINK/ LED green<br />

RJ45<br />

Ch0<br />

On<br />

A link is established<br />

(green)<br />

(off)<br />

Off<br />

No link established<br />

ACT/ LED yellow<br />

RJ45<br />

Ch0 (yellow)<br />

Flashing The device sends/receives <strong>Ethernet</strong> frames<br />

Table 50: LEDs EtherCAT Master<br />

LED State Definition for EtherCAT Master for the RUN and ERR LEDs<br />

Indicator state<br />

On<br />

Off<br />

Blinking<br />

Flickering<br />

Single Flash<br />

Double Flash<br />

Definition<br />

The indicator is constantly on.<br />

The indicator is constantly off.<br />

The indicator turns on and off with a frequency of 2,5 Hz: on for<br />

200 ms, followed by off for 200 ms.<br />

The indicator turns on and off with a frequency of approximately<br />

10 Hz: on for approximately 50 ms, followed by off for 50 ms.<br />

The indicator shows one short flash (200 ms) followed by a long<br />

off phase (1,000 ms).<br />

The indicator shows a sequence of two short flashes (each<br />

200 ms), separated by a short off phase (200 ms). The sequence<br />

is finished by a long off phase (1,000 ms).<br />

Table 51: LED State Definition for EtherCAT Master for the RUN and ERR LEDs<br />

<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />

DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011