11.01.2014 Views

cifX Communication Interfaces Real-Time Ethernet - Hilscher

cifX Communication Interfaces Real-Time Ethernet - Hilscher

cifX Communication Interfaces Real-Time Ethernet - Hilscher

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Technical Data 239/274<br />

10.1.2 CIFX 50E-RE<br />

Item<br />

System Interface<br />

(Bus Type)<br />

Dual-Port Memory Size<br />

Function<br />

<strong>Communication</strong><br />

Protocols<br />

CIFX 50E-RE<br />

<strong>Ethernet</strong> Frame Types<br />

Processor netX 500<br />

LEDs<br />

Rotary Switch Slot Number (Card<br />

ID)*<br />

Configuration Software<br />

<strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> Master<br />

Configuration Software<br />

<strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> Slave<br />

PCI-Express, Single-Lane Port, according to [bus spec 2, Hardw. Rev. 3<br />

according Rev. 1.0a or Hardw.-Rev. 4 according Rev. 2.0] and [bus spec 3],<br />

refer to section Overview on the Pin Assignment at the Bus, page 230,<br />

32-Bit width for the data access to the Dual-Port Memory (DPM) , or beginning<br />

from Hardw.-Rev. 4 DMA (Direct Memory Access)<br />

64 KBytes<br />

<strong>Communication</strong> interface with PCI-Express and <strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong> interface<br />

Determined by the loaded firmware<br />

EtherCAT Master, EtherCAT Slave,<br />

EtherNet/IP-Scanner (Master), EtherNet/IP-Adapter (Slave), Open<br />

Modbus/TCP,<br />

Powerlink Controlled Node/Slave,<br />

PROFINET IO-Controller, PROFINET IO-Device,<br />

SERCOS III Master, SERCOS III Slave<br />

<strong>Ethernet</strong> II<br />

SYS, COM 0, COM 1, 2x Link, 2x Activity;<br />

refer also to chapter LED Descriptions, page 200.<br />

To set the Slot Number (Card ID);<br />

(*provided from hardware revision 4 on)<br />

SYCON.net<br />

netX Configuration Tool or SYCON.net<br />

Transmission Rate 10/100 MBit/s, Auto-Negotiation, Auto-Cross-Over, Halfduplex/Fullduplex (100<br />

MBit/s)<br />

Depending on used firmware<br />

<strong>Ethernet</strong> Interface<br />

RJ45 Socket, 10 Base-T, 100 Base-TX, potential free;<br />

refer also to section <strong>Ethernet</strong> Interface, page 219.<br />

Supply Voltage<br />

+3.3 V dc ±5 %/Typ. 800 mA<br />

Dimensions (L x W x D) Beginning with hardware revision 4:<br />

120,0 x 86 x 18,5 mm; [B = 86 mm, as with Rotary Switch Slot Number (Card<br />

ID)].<br />

Up to and including hardware revision 3:<br />

120,0 x 73,2 x 18,5 mm; [B = 73,2 mm, as without Rotary Switch Slot Number<br />

(Card ID)].<br />

Operating Temperature 0 °C ... +55 °C<br />

Environment<br />

The device must be used in a pollution degree 2 environment.<br />

UL Certification<br />

The device is UL 508 certified (UL-File No E221530).<br />

Table 87: Technical Data CIFX 50E-RE<br />

<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />

DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!