Descriptions and Requirements 43/274<br />

3.2.3 Panel Cutout for AIFX Installing<br />

In order to connect the assembly interface AIFX to a <strong>cifX</strong> <strong>Communication</strong><br />

Interface with cable connector <strong>Ethernet</strong> (labeling „\F“), make sure that the<br />

housing panel of the PC or of the connecting device and the front plate of<br />

the <strong>cifX</strong> has an appropriate cutout and holes for fastening the AIFX. The<br />

panel cutout must be dimensioned sufficiently large for the interface,<br />

display or control elements placed on the AIFX. Partial standard cutouts<br />

can be used.<br />

<strong>cifX</strong><br />

Mini PCI („\F“)<br />

Mini PCI Express („\F“)<br />

PCI 104 („\F“)<br />

PC/104 („\F“)<br />

Panel Cutout<br />

at the housing panel of the PC<br />

on the front plate of the <strong>cifX</strong> <strong>Communication</strong> Interface<br />

Table 19: Panel Cutout at the at the housing panel of the PC or on the front plate of the <strong>cifX</strong><br />

<strong>Communication</strong> Interface<br />

<strong>cifX</strong> AIFX Panel Cutout and Holes<br />

CIFX 90-RE\F<br />

CIFX 90E-RE\F<br />

AIFX-RE Required<br />

Cutout<br />

for two RJ45 Sockets<br />

CIFX 104C-RE\F<br />

CIFX 104C-RE-R\F<br />

CIFX 104-RE\F<br />

CIFX 104-RE-R\F<br />

CIFX 104C-RE\F<br />

CIFX 104C-RE-R\F<br />

CIFX 104-RE\F<br />

CIFX 104-RE-R\F<br />

AIFX-DIAG<br />

Important! The panel cutout layout<br />

must also cover the LEDs COM 0 and<br />

COM1 at the AIFX-RE.<br />

Standard D-Sub-15<br />

cutout<br />

Holes 2, distance between the holes 37,3<br />

mm<br />

Further<br />

Information<br />

Required<br />

Cutout<br />

Standard<br />

cutout<br />

Holes<br />

Further<br />

Information<br />

Table 20: Required Panel Cutout and Holes for AIFX<br />

In the data sheet MOD JACK – MJIM<br />

[2], as well as in section AIFX-RE<br />

Dimensioning on page 215.<br />

for the light channels, the rotary<br />

switches and the Mini B USB plug<br />

-<br />

2, distance between the holes<br />

47,1 mm<br />

in section AIFX-DIAG Dimensioning<br />

on page 217.<br />

<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />

DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011