11.01.2014 Views

cifX Communication Interfaces Real-Time Ethernet - Hilscher

cifX Communication Interfaces Real-Time Ethernet - Hilscher

cifX Communication Interfaces Real-Time Ethernet - Hilscher

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical Data 246/274<br />

10.1.9 AIFX-RE<br />

Item<br />

AIFX-RE<br />

Function<br />

Assembly interface <strong>Ethernet</strong>;<br />

refer also to section Assembly Interface , page 215.<br />

Interface<br />

For:<br />

<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Real</strong>- CIFX 90-RE\F, CIFX 90E-RE\F,<br />

<strong>Time</strong> <strong>Ethernet</strong><br />

CIFX 104C-RE\F, CIFX 104C-RE-R\F,<br />

CIFX 104-RE\F, CIFX 104-RE-R\F:<br />

Cable Connector <strong>Ethernet</strong> for connecting AIFX-RE<br />

LEDs<br />

COM 0, COM 1 (on the reverse side of the device);<br />

refer also to chapter LED Descriptions, page 200.<br />

Transmission Rate 10/100 MBit/s, Auto-Negotiation, Auto-Cross-Over, Halfduplex/Fullduplex (100<br />

MBit/s)<br />

Depending on used firmware<br />

<strong>Ethernet</strong> Interface<br />

RJ45 Socket, 10 Base-T, 100 Base-TX, potential free;<br />

refer also to section <strong>Ethernet</strong> Interface, page 219.<br />

Dimensions (L x W x D)<br />

30,7 x 42,3 x 18,5 mm<br />

Operating Temperature -20 °C ... +70 °C<br />

Environment<br />

The device must be used in a pollution degree 2 environment.<br />

UL Certification<br />

The device is UL 508 certified (UL-File No E221530).<br />

Table 94: Technical Data AIFX-RE<br />

10.1.10 AIFX-DIAG<br />

Item<br />

Function<br />

Assembly Interface<br />

USB Interface<br />

AIFX-DIAG<br />

Assembly Interface; refer also to section Assembly Interface Diagnostic (AIFX-<br />

DIAG), page 217.<br />

For:<br />

CIFX 104C-RE\F, CIFX 104C-RE-R\F,<br />

CIFX 104-RE\F, CIFX 104-RE-R\F:<br />

Cable Connector DIAG<br />

For:<br />

CIFX 104C-RE\F (only for future hardware revisions),<br />

CIFX 104C-RE-R\F(only for future hardware revisions),<br />

CIFX 104-RE\F, CIFX 104-RE-R\F:<br />

Mini B USB Plug (5 pin); refer also to section Mini-B USB Connector (5 Pin),<br />

page 221.<br />

Note! Currently any <strong>cifX</strong> firmware that supports USB can be provided.<br />

Dimensions (L x W x D)<br />

20,5 x 52,7 x 18,5 mm<br />

Operating Temperature -20 °C ... +70 °C<br />

LEDs<br />

SYS, COM 0/COM 1 (<strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong>), ON<br />

Environment<br />

The device must be used in a pollution degree 2 environment.<br />

UL Certification<br />

The device is UL 508 certified (UL-File No E221530).<br />

Table 95: Technical Data AIFX-DIAG<br />

<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />

DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011