Technical Data 246/274<br />
10.1.9 AIFX-RE<br />
Item<br />
AIFX-RE<br />
Function<br />
Assembly interface <strong>Ethernet</strong>;<br />
refer also to section Assembly Interface , page 215.<br />
Interface<br />
For:<br />
<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Real</strong>- CIFX 90-RE\F, CIFX 90E-RE\F,<br />
<strong>Time</strong> <strong>Ethernet</strong><br />
CIFX 104C-RE\F, CIFX 104C-RE-R\F,<br />
CIFX 104-RE\F, CIFX 104-RE-R\F:<br />
Cable Connector <strong>Ethernet</strong> for connecting AIFX-RE<br />
LEDs<br />
COM 0, COM 1 (on the reverse side of the device);<br />
refer also to chapter LED Descriptions, page 200.<br />
Transmission Rate 10/100 MBit/s, Auto-Negotiation, Auto-Cross-Over, Halfduplex/Fullduplex (100<br />
MBit/s)<br />
Depending on used firmware<br />
<strong>Ethernet</strong> Interface<br />
RJ45 Socket, 10 Base-T, 100 Base-TX, potential free;<br />
refer also to section <strong>Ethernet</strong> Interface, page 219.<br />
Dimensions (L x W x D)<br />
30,7 x 42,3 x 18,5 mm<br />
Operating Temperature -20 °C ... +70 °C<br />
Environment<br />
The device must be used in a pollution degree 2 environment.<br />
UL Certification<br />
The device is UL 508 certified (UL-File No E221530).<br />
Table 94: Technical Data AIFX-RE<br />
10.1.10 AIFX-DIAG<br />
Item<br />
Function<br />
Assembly Interface<br />
USB Interface<br />
AIFX-DIAG<br />
Assembly Interface; refer also to section Assembly Interface Diagnostic (AIFX-<br />
DIAG), page 217.<br />
For:<br />
CIFX 104C-RE\F, CIFX 104C-RE-R\F,<br />
CIFX 104-RE\F, CIFX 104-RE-R\F:<br />
Cable Connector DIAG<br />
For:<br />
CIFX 104C-RE\F (only for future hardware revisions),<br />
CIFX 104C-RE-R\F(only for future hardware revisions),<br />
CIFX 104-RE\F, CIFX 104-RE-R\F:<br />
Mini B USB Plug (5 pin); refer also to section Mini-B USB Connector (5 Pin),<br />
page 221.<br />
Note! Currently any <strong>cifX</strong> firmware that supports USB can be provided.<br />
Dimensions (L x W x D)<br />
20,5 x 52,7 x 18,5 mm<br />
Operating Temperature -20 °C ... +70 °C<br />
LEDs<br />
SYS, COM 0/COM 1 (<strong>Real</strong>-<strong>Time</strong> <strong>Ethernet</strong>), ON<br />
Environment<br />
The device must be used in a pollution degree 2 environment.<br />
UL Certification<br />
The device is UL 508 certified (UL-File No E221530).<br />
Table 95: Technical Data AIFX-DIAG<br />
<strong>cifX</strong> <strong>Communication</strong> <strong>Interfaces</strong> <strong>Ethernet</strong> | Installation, Operation and Hardware Description<br />
DOC060501UM30EN | Revision 30 | English | 2011-06 | Released | Public © <strong>Hilscher</strong>, 2006-2011