<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />

a state transition ends in state "active" or in state "unknown" (if <strong>AT</strong>^SCFG<br />

setting ="restricted") when any state transition (including transitions<br />

beginning or ending in state "unknown") occurs in the list of active calls, or<br />

when a voice channel is established (if <strong>AT</strong>^SCFG setting ="verbose").<br />

Due to compatibility considerations, the power up default for <strong>AT</strong>^SCFG<br />

setting is "restricted", offering compatibility to the standard<br />

behaviour of indicator ""+CIEV": call", while the default for setting <br />

is "verbose".<br />

In order to see the URCs, event reporting for both indicators must be<br />

explicitely configured with the appropriate <strong>AT</strong> commands.<br />

6.2 <strong>AT</strong>A Answer a call<br />

Syntax<br />

Exec Command<br />

<strong>AT</strong>A<br />

Reference(s) PIN ASC0<br />

V.25ter ● ●<br />

Response(s)<br />

In case of data call, if successfully connected:<br />

CONNECT TA switches to data mode. In<br />

case of voice call, if successfully connected:<br />

OK<br />

When TA returns to command mode after call<br />

release:<br />

OK<br />

If no connection:<br />

NO CARRIER<br />

Command <strong>Description</strong><br />

TA causes remote station to go off-hook (e.g. answer call).<br />

Parameter <strong>Description</strong><br />

(str)<br />

Connection status<br />

output only if <strong>AT</strong>X parameter setting with value greater 0.<br />

Notes<br />

• Any additional commands on the same command line are ignored.<br />

• The command may be aborted generally by receiving a character<br />

during execution. It can't be aborted in some connection setup states,<br />

such as handshaking.<br />

• For calls explicitly signalled as voice or data calls, this procedure<br />

will fail with result code "NO CARRIER", but the call in question<br />

will continue to ring.<br />

It is possible to change the setting for <strong>AT</strong>+FCLASS to 0 while the call<br />

is ringing, and accept the call normally afterwards with <strong>AT</strong>A.<br />

• The <strong>AT</strong>A command may be used also to accept a network request<br />

for a PDP context activation (see <strong>AT</strong>A).<br />

• See also <strong>AT</strong>X for .<br />

This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.<br />