<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />
Command <strong>Description</strong><br />
The Test command returns the supported parameters.<br />
Use this command to lock, unlock or interrogate a network or ME<br />
. The command can be aborted when network facilities are<br />
being set or interrogated.<br />
Parameter <strong>Description</strong><br />
(str)<br />
Phone security locks set by client or factory<br />
Primarily intended for the client to take safety precautions, "SC",<br />
"PS" and "FD" can be configured individually.<br />
"PS" may also be factory set.<br />
Parameter is not applicable to security locks.<br />
See examples below for further details.<br />
"SC" SIM (lock SIM cards). SIM requests password<br />
upon ME power-up and when this lock command<br />
is issued. : SIM PIN1.<br />
"PS" Phone locked to SIM card. ME requests password<br />
when other than current SIM card is inserted.<br />
"PS" lock is frequently referred to as "phone lock",<br />
or "device lock". Accordingly, the password may<br />
be called "phone code" or "device code". The "PS"<br />
password is not associated with the PUK of the<br />
SIM card. If incorrectly entered three times, the<br />
Master Phone Code is required to lift the lock. This<br />
is an 8-digit device code associated to the IMEI<br />
number of the mobile which can only by obtained<br />
from the manufacturer of the module. Once the<br />
Master Phone Code has been acctepted, the mobile<br />
is operational, and the "PS" lock is no longer<br />
active. If needed it must be set once again.<br />
: User defined password. It is needed<br />
before the first use of "PS" and,<br />
therefore, must first be specified with <strong>AT</strong>+CPWD or<br />
<strong>AT</strong>^SPWD, if it has not been predefined by factory<br />
settings. If set by factory (e.g. for a prepaid<br />
mobile), the password is supplied by the provider<br />
or operator.<br />
"FD" SIM fixed dialling memory: If the mobile is locked<br />
to "FD", only the phone numbers stored to the<br />
"FD" memory can be dialled. (Capacity of FD<br />
phone book depending on the SIM card.)<br />
: SIM PIN 2. If a lock on the SIM<br />
fixed dialing memory is active, the following<br />
applies:<br />
� Outgoing voice, data or fax calls can be made only to<br />
numbers stored in "FD" phone book.<br />
Result code depends on the type of the call:<br />
for voice calls, indication is "+CME Error 257: Call<br />
barred".<br />
For data and fax calls, indication is "NO CARRIER".<br />
This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.<br />