01.11.2012 Views

C55/C55i AT COMMAND SET Description Preliminary - Falcom

C55/C55i AT COMMAND SET Description Preliminary - Falcom

C55/C55i AT COMMAND SET Description Preliminary - Falcom

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />

3.4 <strong>AT</strong>&S Set circuit Data Set Ready (DSR) function mode<br />

Syntax<br />

Exec Command<br />

<strong>AT</strong>&S[]<br />

Response(s)<br />

OK<br />

Reference(s) PIN ASC0<br />

V.25ter ○ ●<br />

Command <strong>Description</strong><br />

This parameter determines how the TA sets circuit 107 (DSR)<br />

depending on the communication state of the TA interfacing TE.<br />

Parameter <strong>Description</strong><br />

(num)(&W)(&V)<br />

[0] (&F) DSR line is always ON<br />

1 TA in command mode: DSR is OFF. TA in data mode:<br />

DSR is ON.<br />

3.5 <strong>AT</strong>E Enable command echo<br />

Syntax<br />

Exec Command<br />

<strong>AT</strong>E[]<br />

Response(s)<br />

OK<br />

Reference(s) PIN ASC0<br />

V.25ter ○ ●<br />

Command <strong>Description</strong><br />

This setting determines whether or not the TA echoes characters<br />

received from TE during command state.<br />

Parameter <strong>Description</strong><br />

(num)(&W)(&V)<br />

[0] Echo mode off<br />

1 (&F)<br />

Echo mode on<br />

Note<br />

• In case of using the command without parameter, is set to 0.<br />