<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />

information is received from the new base station, the default values<br />

will be shown instead: cell="0000", NCC="-", BCC="-".<br />

If the BS supports frequency hopping during a connection, the<br />

dedicated channel (parameter chann) is not stable. This mode is<br />

indicated by chann = 'h'.<br />

• To some extent, the cell monitoring command <strong>AT</strong>^SMONC covers the<br />

same parameters. The receiving level, for example, can be queried with<br />

both commands. Yet the resulting values may be slightly different, even<br />

though obtained over a time period of a few seconds. This is quite<br />

normal and nothing to worry about, as the cell information is<br />

permanently updated.<br />

• For compatibility with earlier products and to support legacy<br />

applications, any input character may be used to stop the output in<br />

certain cases (depending on the settings of 3.7 and 0.1).<br />

^<br />

7.7 <strong>AT</strong> MONP Monitor neighbour cells<br />

Syntax<br />

Test Command<br />

<strong>AT</strong>^MONP=?<br />

Exec Command<br />

<strong>AT</strong>^MONP<br />

Write Command<br />

<strong>AT</strong>^MONP=<br />

Response(s)<br />

^MONP: (list of supported s)<br />

OK<br />

Response(s) See: 7.7.1<br />

OK<br />

Response(s) See: 7.7.1<br />

OK<br />

Reference(s) PIN ASC0<br />

SIEMENS ○ ●<br />

Command <strong>Description</strong><br />

This command can be used to obtain information of up to six<br />

neighbour cells on request.<br />

This command can be used to retrieve information of up to six<br />

neighbour cells automatically every n seconds. To stop the<br />

presentation type "at" or "<strong>AT</strong>".<br />

Parameter <strong>Description</strong><br />

(num)<br />

<br />

Display period in seconds<br />

1...254<br />

Note<br />

• Due to the fact that not all necessary information of the neighbour<br />

cells can be decoded during a connection, there are several<br />

constraints to be considered:<br />

- Only neighbour cells that have already been visible in IDLE<br />

mode will be further updated, as long as they are still included in<br />

the list.<br />

- Though new neighbour cells can be added to the list (e.g. due to<br />

handover), their C1 and C2 parameters cannot be displayed until<br />