<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />
115200<br />
230400<br />
Notes<br />
• The factory default is autobauding enabled (<strong>AT</strong>+IPR=0) on ASC0. It<br />
will not be restored with <strong>AT</strong>&F.<br />
• The current setting of <strong>AT</strong>+IPR will be preserved when you download<br />
firmware (i.e. a firmware update does not restore the factory setting)<br />
3.7.1 Autobauding<br />
or in the event of power failure.<br />
• Generally, <strong>AT</strong>+IPR should be used as a standalone command. If<br />
nethertheless combinations with other commands on the same<br />
command line cannot be avoided, there are several constraints to be<br />
considered:<br />
- Avoid combinations with the <strong>AT</strong> commands listed in chapter<br />
0.4.2.<br />
- Take into account, that a delay of 100 ms is required between the<br />
response to the last command (e.g. OK) and the next command<br />
on the same line.<br />
- When you enter <strong>AT</strong>+IPR=0, autobauding will be activated after<br />
the response to the last command is received.<br />
- When local echo is active (<strong>AT</strong>E1) and you enter <strong>AT</strong>+IPR=X with<br />
other commands you may encounter the following problem: if<br />
switching to the new bit rate takes effect while a response is<br />
being transmitted, the last bytes may be sent with the new bit<br />
rate and thus, not properly transmitted. The following commands<br />
will be correctly sent at the new bit rate.<br />
• In order to account for greater amounts of data it is recommended to<br />
choose a minimum bit rate of 2400 bps.<br />
• A selected bit rate takes effect after the write commands returns OK.<br />
To take advantage of autobaud mode specific attention must be paid to the<br />
following requirements:<br />
• Synchronization between DTE and DCE<br />
Ensure that DTE and DCE are correctly synchronized and the bit<br />
rate used by the DTE is detected by the DCE (ME). To allow the bit<br />
rate to be synchronized simply use an "<strong>AT</strong>" or "at" string. This is<br />
necessary<br />
- after you have activated autobauding<br />
- when you start up the GSM engine while autobauding is<br />
enabled. It is recommended to wait 3 to 5 seconds before<br />
sending the first <strong>AT</strong> character. Otherwise undefined characters<br />
might be returned.<br />
If you want to use autobauding and autoanswer at the same time,<br />
you can easily enable the DTE-DCE synchronization, when you<br />
activate autobauding first and then configure the autoanswer mode<br />
(<strong>AT</strong>SO * 0).<br />
• Restrictions on autobauding operation<br />
This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.<br />