<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />

1.6 <strong>AT</strong>X Set CONNECT result code format and call monitoring<br />

Syntax<br />

Exec Command<br />

<strong>AT</strong>X[]<br />

Response(s)<br />

OK<br />

Reference(s) PIN ASC0<br />

V.25ter ○ ●<br />

Command <strong>Description</strong><br />

This parameter setting determines whether or not the TA detects the<br />

presence of dial tone and busy signal and whether or not TA transmits<br />

particular result codes.<br />

Parameter <strong>Description</strong><br />

(num)(&W)(&V)<br />

[0] CONNECT result code only returned, dial tone and busy<br />

detection are both disabled.<br />

1 CONNECT result code only returned, dial tone and<br />

busy detection are both disabled.<br />

2 CONNECT result code returned, dial tone<br />

detection is enabled, busy detection is disabled.<br />

3 CONNECT result code returned, dial tone<br />

detection is disabled, busy detection is enabled.<br />

4 (&F) CONNECT result code returned, dial tone and busy<br />

detection are both enabled.<br />

1.7 <strong>AT</strong>Z Set all current parameters to user defined profile<br />

Syntax<br />

Exec Command<br />

<strong>AT</strong>Z[]<br />

Response(s)<br />

OK<br />

Reference(s) PIN ASC0<br />

V.25ter ○ ●<br />

Command <strong>Description</strong><br />

TA sets all current parameters to the user profile stored with <strong>AT</strong>&W. If<br />

a connection is in progress, it will be terminated.<br />

All defined GPRS contexts which are not activated or not online will<br />

be undefined (see <strong>AT</strong>+CGDCONT, <strong>AT</strong>+CGQREQ and <strong>AT</strong>+CGQMIN<br />

command). The user defined profile is stored to the non-volatile<br />

memory.<br />

Parameter <strong>Description</strong><br />

(num)<br />

[0] Reset to user profile<br />

Notes<br />

This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.<br />