01.11.2012 Views

C55/C55i AT COMMAND SET Description Preliminary - Falcom

C55/C55i AT COMMAND SET Description Preliminary - Falcom

C55/C55i AT COMMAND SET Description Preliminary - Falcom

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />

Syntax<br />

Test Command<br />

<strong>AT</strong>+CIND=?<br />

Read Command<br />

<strong>AT</strong>+CIND?<br />

Write Command<br />

<strong>AT</strong>+CIND=[, [, ...]]<br />

Response(s)<br />

+ CIND: (, list of supported<br />

s)[, (, list of supported<br />

s)[,…]]<br />

OK<br />

Response(s)<br />

+ CIND: [, [, ...]]<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

Response(s)<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

Reference(s) PIN ASC0<br />

GSM 07.07 ○ ●<br />

Command <strong>Description</strong><br />

The read command returns the status of the ME indicators.<br />

The write command is used to switch the event report for each<br />

indicator type. The Indicator Event Reports are displayed to the TE<br />

via "+CIEV" which can be enabled using <strong>AT</strong>+CMER.<br />

Parameter <strong>Description</strong><br />

(num)<br />

Integer type value,which shall be in range of corresponding<br />

<br />

(str)<br />

String values and their ranges. More indications are<br />

available via <strong>AT</strong>^SIND. Therefore use of <strong>AT</strong>^SIND for control of all<br />

indications is recommended. The following indications are accessible<br />

via <strong>AT</strong>+CIND:<br />

"battchg" Battery charge level (Note that no battery pins are<br />

provided on the 40-pin connector of <strong>C55</strong> module).<br />

"signal" Signal quality (0..7) or (99) if not measurable. The<br />

indicated value is the bit error rate of the signal received.<br />

If there are bit errors this is not a constant but a estimated<br />

value which will change in time. See also <strong>AT</strong>+CSQ.<br />

"service" Service availability (0-1)<br />

0: Not registered to any network<br />

1: Registered to home network or, if "roam"=1 then<br />

registered to another network<br />

"sounder" Sounder activity (0-1). The indicator provides information<br />

about tones generated in the ME. Value 1 means for<br />

example:<br />

Incoming call - ME is ringing. Note that the URC "+CIEV":<br />

"sounder" indicator will be output only if ringing tones are<br />

activated with <strong>AT</strong>^SRTC.<br />

This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.<br />

Page 47

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!