<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />

Parameter <strong>Description</strong><br />

(num) <br />

a numeric parameter which specifies a particular PDP context<br />

definition (see <strong>AT</strong>+CGDCONT command).<br />

(str)<br />

<br />

a string that identifies the MT in the address space applicable to the<br />

PDP. The address may be static or dynamic.<br />

Note<br />

• If no is specified, the write command will return a list of all<br />

defined contexts.<br />

9.8 <strong>AT</strong>+CGQMIN Quality of Service Profile (Minimum<br />

acceptable)<br />

Syntax<br />

Test Command<br />

<strong>AT</strong>+CGQMIN=?<br />

Read Command<br />

<strong>AT</strong>+CGQMIN?<br />

Write Command<br />

<strong>AT</strong>+CGQMIN=[[,<br />

[, [,<br />

[, [, ]]]]]]<br />

Response(s)<br />

+CGQMIN: , (list of supported<br />

s), (list of supported s),<br />

(list of supported s), (list of<br />

supported s), (list of supported s)<br />

OK<br />

ERROR<br />

+CME ERROR<br />

Response(s)<br />

+ CGQMIN: , , ,<br />

, , <br />

OK<br />

ERROR<br />

+CME ERROR<br />

Response(s)<br />

OK<br />

ERROR<br />

+CME ERROR<br />

Reference(s) PIN ASC0<br />

GSM 07.07 ● ●<br />

Command <strong>Description</strong><br />

The test command returns values supported as a compound value. If<br />

the MT supports several PDP types, the parameter value ranges for<br />

each PDP type are returned on a separate line.<br />

The read command returns the current settings for each defined<br />

context. If no minimum profile was explicitly specified for a context,<br />

simply OK will be returned, but default values will be used for that<br />

context.<br />

This command allows the TE to specify a minimum acceptable<br />

profile which is checked by the MT against the negotiated profile<br />

returned in the Activate PDP Context Accept message.<br />