<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />

3.2 <strong>AT</strong>&C Set circuit Data Carrier Detect (DCD) function mode<br />

Syntax<br />

Exec Command<br />

<strong>AT</strong>&C[]<br />

Response(s)<br />

OK<br />

Reference(s) PIN ASC0<br />

V.25ter ○ ●<br />

Command <strong>Description</strong><br />

This parameter determines how the state of circuit 109 (DCD) relates<br />

to the detection of received line signal from the distant end.<br />

Parameter <strong>Description</strong><br />

(num)(&W)(&V)<br />

[0] DCD line is always ON<br />

1 (&F)<br />

DCD line is ON in the presence of data carrier only<br />

3.3 <strong>AT</strong>&D Set circuit Data Terminal Ready (DTR) function<br />

mode<br />

Syntax<br />

Exec Command<br />

<strong>AT</strong>&D[]<br />

Response(s)<br />

OK<br />

Reference(s) PIN ASC0<br />

V.25ter ○ ●<br />

Command <strong>Description</strong><br />

This parameter determines how the TA responds when circuit 108/2<br />

(DTR) is changed from ON to OFF during data mode.<br />

Parameter <strong>Description</strong><br />

(num)(&W)(&V)<br />

[0] TA ignores status of DTR.<br />

1 ON → OFF on DTR: Change to command mode while<br />

retaining the connected call.<br />

2 (&F) ON → OFF on DTR: Disconnect data call, change to<br />

command mode. During state DTR = OFF is auto-answer<br />

off.<br />