<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />

1.9 <strong>AT</strong> ^ SMSO Switch off mobile station<br />

Syntax<br />

Test Command<br />

<strong>AT</strong>^SMSO=?<br />

Exec Command<br />

<strong>AT</strong>^SMSO<br />

Response(s)<br />

OK<br />

Response(s)<br />

^SMSO: MS OFF<br />

OK<br />

Reference(s) PIN ASC0<br />

SIEMENS ○ ●<br />

Unsolicited Result Code<br />

^SHUTDOWN<br />

Indicates that the power-off procedure is finished and the module will<br />

be switched off within 1 second.<br />

Command <strong>Description</strong><br />

The exec command initiates the power-off procedure. Display of URC<br />

"^SHUTDOWN" verifies that the procedure has completed and the<br />

module has entered the POWER DOWN mode. Therefore, be sure not<br />

to disconnect the operating voltage until VDD is low or until URC<br />

"^SHUTDOWN" is displayed. Otherwise, you run the risk of losing data.<br />

For further details on how to turn off the module see the [2].<br />

Notes<br />

• Do not send any command after this command.<br />

1.10 <strong>AT</strong>+GCAP Request complete TA capabilities list<br />

Syntax<br />

Test Command<br />

<strong>AT</strong>+GCAP=?<br />

Exec Command<br />

<strong>AT</strong>+GCAP<br />

Response(s)<br />

OK<br />

Response(s)<br />

+GCAP: <br />

OK<br />

Reference(s) PIN ASC0<br />

V.25ter ○ ●<br />

Command <strong>Description</strong><br />

TA reports a list of additional capabilities.<br />

Parameter <strong>Description</strong><br />

(str)<br />

e.g.: +CGSM,+FCLASS<br />

Note<br />

• +CGSM: The response text shows which GSM commands of the<br />

ETSI standard are supported.<br />