<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />

15 Hardware related Commands<br />

The <strong>AT</strong> commands described in this chapter are related to the <strong>C55</strong>'s<br />

hardware interface. More information regarding this interface is available<br />

with the "<strong>C55</strong> Hardware Interface <strong>Description</strong>"[1].<br />

15.1 <strong>AT</strong>+CALA Set alarm time<br />

Syntax<br />

Test Command<br />

<strong>AT</strong>+CALA=?<br />

Read Command<br />

<strong>AT</strong>+CALA?<br />

Write Command<br />

<strong>AT</strong>+CALA=[, [,<br />

[, ]]]<br />

Response(s)<br />

+CALA: (list of supported s), (list of<br />

supported s), (list of supported s)<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

Response(s)<br />

+ CALA: [, [, [, ]]]<br />

OK<br />

ERROR<br />

+CME ERROR: <br />

Response(s)<br />

OK<br />

ERROR<br />

+CME ERROR<br />

Reference(s) PIN ASC0<br />

GSM 07.07 ○ ●<br />

Unsolicited Result Codes<br />

URC 1<br />

+CALA: <br />

Indicates reminder message.<br />

URC 2<br />

^SYSSTART ALARM MODE<br />

+CALA: <br />

Indicates ME wake-up into Alarm mode. If autobauding is active<br />

(at+ipr=0) the line "^SYSSTART ALARM MODE" does not<br />

appear, but your individual message will be displayed.<br />

Command <strong>Description</strong><br />

Test command returns supported array index values , alarm<br />

types , and maximum length of the text to be<br />

output.<br />

Read command returns the list of current alarm settings in the ME.<br />

The write command sets an alarm time in the ME. When the alarm is<br />

timed out and executed the ME returns an Unsolicited Result Code<br />

(URC) and the alarm time is reset to "00/01/01,00:00:00".<br />

The alarm can adopt two functions, depending on whether or not you<br />

switch the GSM engine off after setting the alarm:<br />

This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.<br />