01.11.2012 Views

C55/C55i AT COMMAND SET Description Preliminary - Falcom

C55/C55i AT COMMAND SET Description Preliminary - Falcom

C55/C55i AT COMMAND SET Description Preliminary - Falcom

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />

15.1.1 Summary of <strong>AT</strong> commands available in Alarm mode<br />

at+cala Set alarm time.<br />

at+cclk<br />

Set date and time of RTC.<br />

at^sbc In alarm mode, you can query the present current<br />

consumption.<br />

at^sctm Query temperature of GSM engine.<br />

at^smso Power down GSM engine.<br />

Table 17.1: List of <strong>AT</strong> commands available in alarm mode <strong>AT</strong> command<br />

function<br />

15.2 <strong>AT</strong>+CCLK Real Time Clock<br />

Syntax<br />

Test Command<br />

Response(s)<br />

<strong>AT</strong>+CCLK=? OK<br />

Read Command<br />

Response(s)<br />

<strong>AT</strong>+CCLK?<br />

+CCLK: <br />

OK<br />

Write Command<br />

Response(s)<br />

<strong>AT</strong>+CCLK=<br />

+CME ERROR: <br />

ERROR<br />

OK<br />

Reference(s) PIN ASC0<br />

GSM 07.05 ○ ●<br />

Parameter <strong>Description</strong><br />

(str)<br />

Format is "yy/mm/dd,hh:mm:ss", where the characters indicate the two<br />

last digits of the year, followed by month, day, hour, minutes, seconds;<br />

for example 6 May 2004, 22:10:00 hours equals to<br />

"04/05/06,22:10:00" Factory default is "02/01/01,00:00:00"<br />

Notes<br />

• is retained if the device enters the Power Down mode via<br />

<strong>AT</strong>^SMSO.<br />

• will be reset to its factory default if power is totally<br />

disconnected. In this case, the clock starts with =<br />

"02/01/01,00:00:00" upon next power-up.<br />

• Each time <strong>C55</strong> is restarted it takes 2 s to re-initialize the RTC and<br />

to update the current time. Therefore, it is recommended to wait 2 s<br />

before using the commands <strong>AT</strong>+CCLK and <strong>AT</strong>+CALA (for example<br />

2 s after ^ SYSSTART has been output)..<br />