<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />
4.3 <strong>AT</strong> ^ SPIC Display PIN counter<br />
Syntax<br />
Test Command<br />
<strong>AT</strong>^SPIC=?<br />
Read Command<br />
<strong>AT</strong>^SPIC?<br />
Exec Command<br />
<strong>AT</strong>^SPIC<br />
Write Command<br />
<strong>AT</strong>^SPIC=<br />
Response(s)<br />
OK<br />
Response(s)<br />
^SPIC: <br />
OK<br />
Response(s)<br />
^SPIC: <br />
OK<br />
Response(s)<br />
^SPIC: <br />
OK<br />
Reference(s) PIN ASC0<br />
SIEMENS ○ ●<br />
Command <strong>Description</strong><br />
The read command returns an identification of the currently required<br />
password, e.g. the PIN, PUK, PH-SIM PUK etc. The <br />
returned by the execute command refers to this password. In case there<br />
is no currently required password (the responses to "<strong>AT</strong>+CPIN?" and<br />
"<strong>AT</strong>+CPIN2?" both read "READY"), the read command nevertheless<br />
identifies the password to which the execute command response<br />
refers.<br />
The execute command returns the number of attempts still available<br />
for entering the currently required password, e.g. the PIN, PUK, PH-<br />
SIM PUK etc. To check whether or not you need to enter a password<br />
use commands <strong>AT</strong>+CPIN? , Read command <strong>AT</strong>^SPIC? and <strong>AT</strong>+CPIN2?.<br />
If the responses to "<strong>AT</strong>+CPIN?" and "<strong>AT</strong>+CPIN2?" both read "READY",<br />
there is no currently required password, and the referrerof the execute<br />
command "<strong>AT</strong> ^ SPIC" is explicitly undefined.<br />
In these cases, the read command "<strong>AT</strong> ^ SPIC?" may be used to<br />
determine, which password the response of the execute command<br />
actually refers to. Also, the write command may be used in order to<br />
retrieve the counter for a specific password.<br />
The write command returns the number of attempts still available for<br />
entering the password identified by , e.g. the PIN, PIN 2,<br />
PH-SIM PIN etc.<br />
Parameter <strong>Description</strong><br />
(num)<br />
Number of attempts for the currently required password. This number<br />
will be counted down after each failure.<br />
(str)<br />
Password for which the corresponding PIN counter is to be displayed<br />
"SC" SIM PIN or SIM PUK. If the SIM PIN has been<br />
deactivated after three failed attempts, the counter<br />
for SIM PUK will be returned instead.<br />
This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.<br />