01.11.2012 Views

C55/C55i AT COMMAND SET Description Preliminary - Falcom

C55/C55i AT COMMAND SET Description Preliminary - Falcom

C55/C55i AT COMMAND SET Description Preliminary - Falcom

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>C55</strong>/<strong>C55</strong>I <strong>AT</strong> <strong>COMMAND</strong> <strong>SET</strong> VERSION 1.00<br />

OK<br />

<strong>AT</strong>+CCUG? Query new setting<br />

+CCUG: 1,9,1<br />

OK<br />

Example 2:<br />

Using default parameter values for optional parameters<br />

<strong>AT</strong>+CFUN=5, 0 Activate CYCLIC SLEEP mode, don't reset ME<br />

OK<br />

<strong>AT</strong>+CFUN? Query ME mode<br />

+CFUN: 5<br />

OK<br />

<strong>AT</strong>+CFUN= Set ME back to normal (default parameters: 1,0)<br />

OK<br />

+CFUN: 1<br />

OK<br />

0.4.2 Combining <strong>AT</strong> commands on the same command line<br />

You may enter several <strong>AT</strong> commands on the same line. This eliminates the<br />

need to type the "<strong>AT</strong>" or "at" prefix before each command. Instead, it is<br />

only needed once at the beginning of the command line. Use a semicolon as<br />

command delimiter.<br />

The command line buffer accepts a maximum of 391 characters. If this<br />

number is exceeded none of the commands will be executed and TA returns<br />

ERROR.<br />

The table below lists the <strong>AT</strong> commands you cannot enter together with other<br />

commands on the same line. Otherwise, the responses may not be in the<br />

expected order.<br />

<strong>AT</strong> command type Comment<br />

V.25ter commands with FAX commands (Prefix <strong>AT</strong>+F)<br />

GSM 7.07 commands with commands (Prefix <strong>AT</strong>^S)<br />

GSM 7.05 commands (SMS) To be used standalone<br />

Commands starting with <strong>AT</strong>& To be used standalone<br />

<strong>AT</strong>+IPR To be used standalone<br />

Note: When concatenating <strong>AT</strong> commands please keep in mind that the<br />

sequence of processing may be different from the sequential order of<br />

command input. Therefore, if the consecutive order of the issued commands<br />

is your concern, avoid concatenating commands on the same line.<br />

This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.<br />

Page 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!