Playground<br />

H 5.4 Hazards No drainage ditches, pools, drop-<strong>of</strong>f, etc., in play yard M<br />

Center Entrance<br />

H/S/O Ref Item Directive M/R Check<br />

H 6.7.3 Entrance Pathway Main entrance pathways, 6’ to 8’ wide R<br />

H 6.7.3 Paving Maximum slopes: 1:20 without handrail R<br />

H 6.7.3 Maximum Cross slopes: 1:50 R<br />

H 6.7.3 Handrails Use child-scaled handrail heights: 20 to 36 inches. Where<br />

adult handrails are also required, provide two handrails at two<br />

heights.<br />

H 6.7.3 Guardrails Provide guardrails <strong>for</strong> Infants and Toddlers at walk surfaces<br />

differing by 12” or more<br />

H 6.7.3 Provide guardrails <strong>for</strong> <strong>Pre</strong> -Schoolers at walk surfaces<br />

differing by 20” or more<br />

H 6.7.3 Top <strong>of</strong> guardrail 30” above walk surface R<br />

H 6.7.3 Guardrails shall not have openings from 3.4 to 9 inches R<br />

H 6.7.3 Guardrails shall not have openings <strong>for</strong>m 0.3 to 1 inch R<br />

H 6.7.3 Guardrails on plat<strong>for</strong>ms more than 30”, no openings larger<br />

than 3” and no horizontal footholds<br />

H 6.7.3 Plat<strong>for</strong>m Heights Maximum plat<strong>for</strong>m height <strong>for</strong> Infants is 18” R<br />

H 6.7.3 Maximum plat<strong>for</strong>m height <strong>for</strong> Toddlers is 36” R<br />

H 6.7.3 Maximum plat<strong>for</strong>m height <strong>for</strong> <strong>Pre</strong>-Schoolers is 4.5’ (4’-6”) R<br />

H 7.1.6 Entrance Doors Provide safety glass glazing in entrance doors R<br />

H 7.1.8 Entrance Mat Recessed walk-<strong>of</strong>f mat at entrance doors R<br />

H 7.1.7 Bench Provide a bench near doorway <strong>for</strong> child/parent use R<br />

Reception<br />

H/S/O Ref Item Directive M/R Check<br />

R<br />

R<br />

R<br />

R<br />

H 3.3 Location Visible monitoring and control <strong>of</strong> entry R<br />

H 5.6 Security Building entry should be secured and controlled R<br />

H 7.1.6 Vestibule A thermal lock vestibule is desired R<br />

H 7.1.6 Reception Desk Children should have full view <strong>of</strong> person at desk R<br />

H 7.1.6 An adult RR should be easily accessed from this area R<br />

H 7.1.9 Sign-in facility <strong>for</strong> parents R<br />

H 7.1.9 Parent/teacher mailboxes R<br />

H 3.3 Storage Lockable <strong>for</strong> personal items R<br />

H 3.3 Filing Cabinets R