Technical Requirements<br />
Administrative Space<br />
RECEPTION / WAITING AREA (AS-01)<br />
ROOM FUNCTION<br />
This space will serve as the reception area <strong>for</strong> each <strong>of</strong> the<br />
administrative <strong>of</strong>fice suites as identified in the space summary.<br />
An Administrative Assistant will typically monitor this space<br />
and serve as the receptionist <strong>for</strong> visitors.<br />
ROOM DATA<br />
Net Square Feet (ASF)<br />
Avg. No. <strong>of</strong> Occupants<br />
No. <strong>of</strong> Spaces by Type<br />
100 asf<br />
1 + 2 Guests<br />
1 (Eastside); 1 (Westside)<br />
TECHNICAL REQUIREMENTS<br />
ARCHITECTURAL<br />
Floor<br />
Base<br />
Walls<br />
Ceiling<br />
Lighting<br />
MECHANICAL / PLUMBING<br />
Temperature/Humidity<br />
Air Changes/Hour<br />
Hot Water (HW)<br />
Other<br />
Carpet Tile<br />
Rubber<br />
Painted Gypsum Wallboard<br />
Acoustical Tile System<br />
Fluorescent<br />
Variable 68°f to 75°f @ 50%rh<br />
min. per Code<br />
Cold Water (CW)<br />
<strong>SA</strong>MPLE ROOM LAYOUT<br />
This diagram is included as a planning tool to ensure that the space<br />
will function as the users require within the assigned square feet. It is<br />
not intended to dictate the final design or configuration <strong>of</strong> the space.<br />
ELECTRICAL / COMMUNICATIONS<br />
Power 110v/20a/1-phase - See Note 4<br />
Dedicated Circuits<br />
Stand-by Power<br />
Data See Notes 3 and 4<br />
Other<br />
FURNISHINGS, FIXTURES & EQUIPMENT<br />
NOTES (CONTINUED)<br />
(2) Guest Chairs <strong>of</strong>oi 2. Provide vision lite in entry door <strong>for</strong> visual access from the<br />
(1) End Table and / or C<strong>of</strong>fee Table <strong>of</strong>oi<br />
building corridors or adjacent spaces. Entry door to space<br />
shall be provided with secure (i.e. key card) access.<br />
(1) Standard Modular Desk <strong>of</strong>oi<br />
3. Provide (1) 2-port data outlet and (1) telephone outlet<br />
(1) Standard Movable Chair <strong>of</strong>oi (min.) to workstation; coordinate with workstation location.<br />
(1) File Cabinet <strong>of</strong>oi Building shall be equipped with wireless technology and<br />
infrastructure.<br />
(1) Computer and Monitor <strong>of</strong>oi<br />
4. Provide adequate power to workstation to operate equipment;<br />
coordinate with workstation location. Convenience<br />
(1) Telephone <strong>of</strong>oi<br />
Access to Shared Network Printer<br />
<strong>of</strong>oi duplex power outlets shall be provided along the perimeter<br />
walls at regular intervals, in accordance with Code. When<br />
locating power and data outlets, pay special attention to the<br />
possible location <strong>of</strong> equipment and furniture.<br />
5. Provide 50 to 55 footcandle (fc) <strong>for</strong> general illumination.<br />
NOTES<br />
Lighting shall have motion sensors; controls shall be located<br />
within close proximity to the entry door. Natural light into<br />
1. Reference “Code and Standards” chapter <strong>for</strong> in<strong>for</strong>mation the space is desired. Windows shall be provided with blinds or<br />
regarding additional design requirements <strong>of</strong> this space which shades to control natural light.<br />
may not be listed here.<br />
An Architectural Space Program <strong>for</strong> the <strong>City</strong> <strong>of</strong> <strong>San</strong> <strong>Antonio</strong><br />
Facility <strong>Programming</strong> and Consulting<br />
<strong>Pre</strong>-K 4 <strong>SA</strong> Early Childhood Centers - East and Westside Centers Final - May 2013<br />
Page 4.14