Technical Requirements<br />
Building Support Functions<br />
LOBBY / RECEPTION AREA (BS-01)<br />
ROOM FUNCTION<br />
This space will serve as the first point <strong>of</strong> interaction <strong>for</strong> the<br />
students, faculty and guests visiting the Center. In addition to<br />
serving as an in<strong>for</strong>mation station, the Receptionist housed in<br />
this area will serve as a secure, controlled access point <strong>for</strong> anyone<br />
entering the facility.<br />
ROOM DATA<br />
Net Square Feet (ASF)<br />
Avg. No. <strong>of</strong> Occupants<br />
No. <strong>of</strong> Spaces by Type<br />
300 asf<br />
1 Staff + Guests (Number Varies)<br />
1 (Eastside); 1 (Westside)<br />
TECHNICAL REQUIREMENTS<br />
ARCHITECTURAL<br />
Floor<br />
Base<br />
Walls<br />
Ceiling<br />
Lighting<br />
MECHANICAL / PLUMBING<br />
Temperature/Humidity<br />
Air Changes/Hour<br />
Hot Water (HW)<br />
Other<br />
Resilient Flooring<br />
Rubber<br />
Painted Gypsum Wallboard<br />
Acoustical Tile System<br />
Fluorescent<br />
Variable 68°f to 75°f @ 50%rh<br />
min. per Code<br />
Cold Water (CW)<br />
<strong>SA</strong>MPLE ROOM LAYOUT<br />
This diagram is included as a planning tool to ensure that the space<br />
will function as the users require within the assigned square feet. It is<br />
not intended to dictate the final design or configuration <strong>of</strong> the space.<br />
ELECTRICAL / COMMUNICATIONS<br />
Power 110v/20a/1-phase - See Notes 6, 7<br />
Dedicated Circuits<br />
Stand-by Power<br />
Data See Note 5 and 7<br />
Other<br />
FURNISHINGS, FIXTURES & EQUIPMENT<br />
NOTES (CONTINUED)<br />
Lounge Seating <strong>of</strong>oi 4. Consideration should be given to the upgrade <strong>of</strong> finishes in<br />
(1) Built-In Reception Desk (ADA Compliant) cfci this area since it will represent the Center to the public. Finishes<br />
should be tasteful, durable and appropriate.<br />
(1) Standard Rolling Task Chair <strong>of</strong>oi<br />
5. Provide (2) 2-port data outlets (min.) on two perimeter<br />
(1) Computer and Monitor <strong>of</strong>oi walls. Provide (1) 2-port data outlet and (1) telephone outlet<br />
(1) Telephone <strong>of</strong>oi (min.) to workstation; coordinate with workstation location.<br />
Ceiling-Mounted Surveillance Cameras<br />
<strong>of</strong>ci<br />
Building shall be equipped with wireless technology and<br />
infrastructure.<br />
NOTES<br />
6. Provide power and data at location <strong>of</strong> surveillance cameras.<br />
1. Reference “Code and Standards” chapter <strong>for</strong> in<strong>for</strong>mation<br />
regarding additional design requirements <strong>of</strong> this space which<br />
may not be listed here.<br />
2. Provide vestibule at building entry to Lobby to maintain airlock<br />
and reduce impact from outside environment. Entry<br />
doors to space shall be provided with secure (i.e. key card)<br />
access.<br />
3. Consideration should be given to the utilization <strong>of</strong> a glass<br />
storefront to increase visibility into this space. Space should be<br />
inviting to guests but maintain a pr<strong>of</strong>essional atmosphere.<br />
Coordinate number and location with User.<br />
7. Provide adequate power to computer workstation to operate<br />
equipment; coordinate with workstation location. Convenience<br />
duplex power outlets shall be provided along the<br />
perimeter walls at regular intervals, in accordance with<br />
Code. When locating power and data outlets, pay special<br />
attention to the possible location <strong>of</strong> equipment and furniture.<br />
8. Provide 50 to 55 fc <strong>for</strong> general illumination. Lighting controls<br />
shall be located in close proximity to the entry door. Provide<br />
windows with blinds or shades to control natural light.<br />
An Architectural Space Program <strong>for</strong> the <strong>City</strong> <strong>of</strong> <strong>San</strong> <strong>Antonio</strong><br />
Facility <strong>Programming</strong> and Consulting<br />
<strong>Pre</strong>-K 4 <strong>SA</strong> Early Childhood Centers - East and Westside Centers Final - May 2013<br />
Page 4.34