Technical Requirements<br />

Administrative Space<br />

CONFERENCE ROOM (AS-05)<br />

ROOM FUNCTION<br />

This space will be used <strong>for</strong> meetings with departmental staff,<br />

vendors or outside guests. Conference Room will be located<br />

within administrative suite <strong>for</strong> use by that department /<br />

program.<br />

ROOM DATA<br />

Net Square Feet (ASF) 160 asf<br />

Avg. No. <strong>of</strong> Occupants 8<br />

No. <strong>of</strong> Spaces by Type 1 (Eastside); 1 (Westside)<br />

TECHNICAL REQUIREMENTS<br />

ARCHITECTURAL<br />

Floor<br />

Base<br />

Walls<br />

Ceiling<br />

Lighting<br />

MECHANICAL / PLUMBING<br />

Temperature/Humidity<br />

Air Changes/Hour<br />

Hot Water (HW)<br />

Other<br />

Carpet Tile<br />

Rubber<br />

Painted Gypsum Wallboard<br />

Acoustical Tile System<br />

Fluorescent<br />

Variable 68°f to 75°f @ 50%rh<br />

min. per Code<br />

Cold Water (CW)<br />

<strong>SA</strong>MPLE ROOM LAYOUT<br />

This diagram is included as a planning tool to ensure that the space<br />

will function as the users require within the assigned square feet. It is<br />

not intended to dictate the final design or configuration <strong>of</strong> the space.<br />

ELECTRICAL / COMMUNICATIONS<br />

Power 110v/20a/1-phase - See Note 4<br />

Dedicated Circuits<br />

Stand-by Power<br />

Data See Notes 3 and 4<br />

Other<br />

FURNISHINGS, FIXTURES & EQUIPMENT<br />

(1) Standard Movable Conference Table <strong>of</strong>oi 1. Reference “Code and Standards” chapter <strong>for</strong> in<strong>for</strong>mation<br />

(8) Standard Movable Chairs <strong>of</strong>oi<br />

regarding additional design requirements <strong>of</strong> this space which<br />

may not be listed here.<br />

(1) 55” Flat Screen TV / DVD (Wall Mounted) <strong>of</strong>ci<br />

2. Provide vision lite in entry door <strong>for</strong> visual access from the<br />

Tackable Wall Surface - 4 Linear Feet (min.)<br />

cfci building corridors or adjacent spaces. Entry door to space<br />

Whiteboard Surface - 8 Linear Feet (min.)<br />

cfci shall be provided with keyed lock.<br />

3. Provide (2) 2-port data outlets and (1) telephone outlet<br />

(min.) on two perimeter walls. Building shall be equipped<br />

with wireless technology and infrastructure.<br />

*Note: Flat screen TV is intended to be utilized <strong>for</strong> projection.<br />

Provide data input connection at perimeter wall in vicinity <strong>of</strong><br />

the television.<br />

4. Convenience duplex power outlets shall be provided along<br />

the perimeter walls at regular intervals, in accordance with<br />

Code. When locating power and data outlets, pay special<br />

attention to the possible location <strong>of</strong> equipment and furniture.<br />

5. Provide 50 to 55 fc <strong>for</strong> general illumination; 20 fc <strong>for</strong> note taking<br />

during projection. Lighting shall have motion sensors;<br />

controls shall be located within close proximity to the entry<br />

door. Natural light into the space is desired. Windows shall be<br />

provided with blinds or shades to control natural light.<br />

NOTES<br />

An Architectural Space Program <strong>for</strong> the <strong>City</strong> <strong>of</strong> <strong>San</strong> <strong>Antonio</strong><br />

Facility <strong>Programming</strong> and Consulting<br />

<strong>Pre</strong>-K 4 <strong>SA</strong> Early Childhood Centers - East and Westside Centers Final - May 2013<br />

Page 4.18