Children’s Classroom Toilet<br />

H 7.7.2 Counter top depth, 16” to 22” R<br />

H 7.7.2 Hot water temperature, maximum 109.4 degrees R<br />

R<br />

H 10.11.2 Accessories Mirrors: Mounted over sink, 29.5” bottom edge to floor. All<br />

mirrors shatterpro<strong>of</strong>.<br />

H 7.7.2 Provide paper towel dispenser at each sink. Metered roll<br />

dispensers are preferred. No serrated tear edges allowed<br />

H 7.7.2 Provide soap dispensers at each sink R<br />

H 10.11.2 Toilet paper dispensers: Mount 14” above floor R<br />

M<br />

H 7.7.2 Toddlers Minimum 2 adult sinks, (1) diapering and (1) food<br />

preparation<br />

H 7.7.2 <strong>Pre</strong>schoolers Minimum 1 adult sink, 1 or 2 hand washing sinks <strong>for</strong> every<br />

10-20 children.<br />

H 7.1.15 ADA Meet all ADA requirements R<br />

H 7.7.2 Doors Doors should not lock in toilets R<br />

H 7.7.2 Doors or gates should be half height R<br />

H 7.7.2 Door hardware should have hinge protection to prevent<br />

hand/finger crushing<br />

H 7.7.2 Floor Drain Provide floor drain in toilet rooms R<br />

Provide exhaust ventilation in toilet areas<br />

R<br />

H 7.7.2 Exhaust<br />

Ventilation<br />

H (Ap A) Plumbing Maximum toilet height: 11” R<br />

R<br />

H 10.11.2 Water closet flushing controls: Front mounted, 20 to 30<br />

above floor.<br />

Office – Director<br />

H/S/O Ref Item Directive M/R Check<br />

R<br />

M<br />

R<br />

H 4.1.5 Purpose Administrative space <strong>for</strong> center director R<br />

H 7.1.12 Meet with parents, staff members, children R<br />

H 4.1.5 Location Facilitate frequent contact with children, parents, staff R<br />

H 7.1.12 Locate near reception, accessible to visitors R<br />

H 7.1.12 Desirable to have views <strong>of</strong> main entry receptions and<br />

classrooms<br />

H 7.1.12 Floors Carpet R<br />

H 7.1.12 Walls Washable R<br />

H 7.1.12 Acoustical Acoustical separation <strong>of</strong> at least 45 STC from children’s area R<br />

H 7.1.12 Furnishing Desk, hair, two side chairs, filing cabinet, coat rack, book<br />

shelving, lockable storage cabinet or closet <strong>for</strong> personal items<br />

& first aid<br />

H 3.3 Equipment Telephone, security video monitors, computer, and printer. R<br />

H 3.3 Copier and fax machine if not located elsewhere R<br />

R<br />