Classroom – <strong>Pre</strong>-School (Head Start)<br />

H 7.5.6 Mirrors Provide child shatterpro<strong>of</strong> mirror, minimum 1.5’ high. No<br />

sharp edges<br />

H 10.11.2 Full-length mirror, 18” above floor. All mirrors shatterpro<strong>of</strong>. R<br />

H 7.7.7 Drinking Fount Provide room temperature drinking fountain R<br />

H 7.7.7 Mount drinking fountain at 1.8’ (1’-10”) above floor R<br />

H 7.7.1 Children’s Sink Children’s sink cabinet, 22” high, 16” to 22” deep, 3’ to 4’<br />

countertop length adjacent to sink. (See also Plumbing)<br />

H 7.4 Plumbing Group plumbing fixtures in one area. Separate food prep<br />

from diaper changing areas<br />

H 7.7.1 Children’s sink, stainless steel, goose-neck faucet, wrist<br />

handles, mounted 22” above floor. Counter, 16” to 22” deep.<br />

H 7.7.7 Provide room temperature drinking fountain 1.8’ (1’-10”)<br />

A.F.F.<br />

H 7.7.2 Provide water play plumbing connection R<br />

R<br />

H 3.2 Electrical Duplexes – Elevated outlets <strong>for</strong> TV, tapes, etc. Minimum 4.5’<br />

above finish floor<br />

H 3.5.1 Lighting - Dimmable lighting. (See “Natural Light” above) R<br />

H 7.3 General pendent lighting/ceiling fans, no lower than 7.5 feet R<br />

H 7.3 Pendent task lighting, no lower than 5.5 feet R<br />

Children’s Classroom Toilet<br />

H/S/O Ref Item Directive M/R Check<br />

R<br />

R<br />

R<br />

R<br />

R<br />

H 7.3 Location Locate in classroom area, separated from food preparation R<br />

H 7.7.2 Toilets should be partially screened from main classroom R<br />

H 7.7.2 Two classrooms can share one toilet area R<br />

H 7.7.2 Toddlers: Use child scaled fixtures. WC seats, 11” high. R<br />

H 7.7.2 <strong>Pre</strong>schoolers: Use adult WC R<br />

H 7.7.2 Flooring Impervious flooring. Ceramic tile floor, base, wainscot to 3’<br />

high, painted wall above.<br />

H 7.1.15 Walls Impervious wainscot, paint above R<br />

M<br />

H 7.7.2 Water Closets Minimum 1 toilet, 2 child height hand washing sinks in each<br />

classroom<br />

H (Ap A) Toilets: Provide at a ratio <strong>of</strong> roughly 1:10 <strong>for</strong> toddlers and<br />

preschoolers.<br />

H (Ap A) Maximum toilet height: 11” R<br />

R<br />

H 10.11.2 Water closet flushing controls: Front mounted, 20 to 30<br />

above floor.<br />

H 7.7.2 Lavs/Hand Sinks One lavatory, one drinking fountain per every 10 children M<br />

R<br />

H 7.7.2 Hand washing sinks can be located within toilet area, but best<br />

located in classroom on wall adjacent to toilet area<br />

H 7.7.2 Mount sink 22” above floor. R<br />

H (Ap A) Maximum children hand sink height: 22” R<br />

R<br />