Technical Requirements<br />

Instructional Space<br />

GENERAL CLASSROOM - TEACHER’S STORAGE CLOSET (WALK-IN) (IS-01C)<br />

ROOM FUNCTION<br />

In addition to storage <strong>of</strong> general classroom materials, this<br />

space will provide walk-in storage <strong>for</strong> the instructor’s personal,<br />

supplemental educational materials, as well as storage <strong>for</strong> personal<br />

belongings during the workday.<br />

ROOM DATA<br />

Net Square Feet (ASF)<br />

Avg. No. <strong>of</strong> Occupants<br />

No. <strong>of</strong> Spaces by Type<br />

25 asf<br />

n/a<br />

25 (Eastside); 25 (Westside)<br />

TECHNICAL REQUIREMENTS<br />

ARCHITECTURAL<br />

Floor<br />

Base<br />

Walls<br />

Ceiling<br />

Lighting<br />

MECHANICAL / PLUMBING<br />

Temperature/Humidity<br />

Air Changes/Hour<br />

Hot Water (HW)<br />

Other<br />

Resilient Flooring<br />

Rubber<br />

Painted Gypsum Wallboard<br />

Acoustical Tile System<br />

Fluorescent<br />

Variable 68°f to 75°f @ 50%rh<br />

min. per Code<br />

Cold Water (CW)<br />

<strong>SA</strong>MPLE ROOM LAYOUT<br />

This diagram is included as a planning tool to ensure that the space<br />

will function as the users require within the assigned square feet. It is<br />

not intended to dictate the final design or configuration <strong>of</strong> the space.<br />

ELECTRICAL / COMMUNICATIONS<br />

Power 110v/20a/1-phase - See Note 4<br />

Dedicated Circuits<br />

Data<br />

Other<br />

Stand-by Power<br />

FURNISHINGS, FIXTURES & EQUIPMENT<br />

NOTES<br />

Industrial Metal Shelving OR <strong>of</strong>oi 1. Reference “Code and Standards” chapter <strong>for</strong> in<strong>for</strong>mation<br />

Built-In Shelving (12” Deep min.)<br />

cfci<br />

regarding additional design requirements <strong>of</strong> this space which<br />

may not be listed here.<br />

(1) Coat Hook (Door Mounted on Closet Interior) cfci<br />

2. Space should be located adjacent to and accessible from the<br />

(1) Mirror (12” x 30”; Door Mounted on Closet Interior) cfci Instructional Area. Door swing from closet may not intrude<br />

(20) Yoga Mats (<strong>for</strong> Children’s Naptime) <strong>of</strong>oi upon or obstruct the required minimum clear floor area (720<br />

asf) <strong>of</strong> the Instructional Area. Entry door to space shall be<br />

provided with keyed lock.<br />

3. Provide 50 to 55 footcandle (fc) <strong>for</strong> general illumination.<br />

Lighting shall have motion sensors; controls shall be located<br />

within close proximity to the entry door.<br />

4. Convenience duplex power outlets shall be provided along<br />

the perimeter walls at regular intervals, in accordance with<br />

Code.<br />

5. This space does not require natural light.<br />

An Architectural Space Program <strong>for</strong> the <strong>City</strong> <strong>of</strong> <strong>San</strong> <strong>Antonio</strong><br />

Facility <strong>Programming</strong> and Consulting<br />

<strong>Pre</strong>-K 4 <strong>SA</strong> Early Childhood Centers - East and Westside Centers Final - May 2013<br />

Page 4.8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!