Code and Standards<br />

children’s artwork or <strong>for</strong> delineated zones <strong>for</strong> children to line up<br />

be<strong>for</strong>e field trips.<br />

Mechanical Design Considerations<br />

1. By <strong>City</strong> Ordinance (2009-03-12-0179), with the goal <strong>of</strong> net-zero<br />

carbon by 2030, effective January 1, 2010, non-residential construction<br />

must achieve an efficiency rate <strong>of</strong> 15% above the current <strong>City</strong><br />

<strong>of</strong> <strong>San</strong> <strong>Antonio</strong> energy code that was in effect in 2008 (IECC 2000<br />

with 2001 supplement and ASHRAE 90.1 1999).<br />

2. Condensing units shall be located and/or screened in a manner<br />

which minimizes visual impact.<br />

3. Consider the use <strong>of</strong> passive heating and cooling methods to increase<br />

energy conservation.<br />

4. Fresh air shall be supplied and spaces ventilated in accordance with<br />

the International Mechanical Code.<br />

5. An interior environment with variable temperature range between<br />

68° to 75° Fahrenheit is desired. Design HVAC system accordingly<br />

to achieve this temperature, especially in areas which contain a large<br />

number <strong>of</strong> heat-producing equipment or computer workstations.<br />

System should have a master set point that can be used, as well as<br />

individual set points that can be used to override an individual<br />

room as needed.<br />

6. Design HVAC system so that excessive air flow or equipment noise<br />

within one space shall not intrude into adjacent spaces.<br />

Plumbing Design Considerations<br />

1. Ro<strong>of</strong> drains, gutters and downspouts should be designed to carry<br />

storm water away from building foundation and to a storm water<br />

collection system, such as a French drain, sump pump or <strong>City</strong><br />

storm sewer. Consideration should be given to the design <strong>of</strong> a<br />

system which allows the collection / harvesting <strong>of</strong> this rain water<br />

<strong>for</strong> landscape irrigation use.<br />

2. Where applicable, fixtures which utilize water conservation features<br />

shall be installed.<br />

Electrical Design Considerations<br />

1. Adequate site lighting shall be provided at the project site perimeter,<br />

within parking areas and at building entrances to maintain a<br />

com<strong>for</strong>table level <strong>of</strong> security.<br />

2. Emergency and exit lighting shall be provided per NFPA 101<br />

requirements.<br />

An Architectural Space Program <strong>for</strong> the <strong>City</strong> <strong>of</strong> <strong>San</strong> <strong>Antonio</strong><br />

Facility <strong>Programming</strong> and Consulting<br />

<strong>Pre</strong>-K 4 <strong>SA</strong> Early Childhood Centers - East and Westside Centers Final - May 2013<br />