Technical Requirements<br />

Administrative Space<br />

WORKROOM / GENERAL STORAGE (AS-07)<br />

ROOM FUNCTION<br />

This space type will provide an area <strong>for</strong> the location <strong>of</strong> shared<br />

equipment (copy, fax, etc.), departmental mailboxes, supply<br />

storage, and/or document assembly/production space. <strong>The</strong><br />

space should be designed with the flexibility <strong>for</strong> future conversion<br />

to <strong>of</strong>fice space, if necessary.<br />

TECHNICAL REQUIREMENTS<br />

ARCHITECTURAL<br />

Floor<br />

Base<br />

Walls<br />

Ceiling<br />

Lighting<br />

Resilient Flooring<br />

Rubber<br />

Painted Gypsum Wallboard<br />

Acoustical Tile System<br />

Fluorescent<br />

ROOM DATA<br />

Net Square Feet (ASF)<br />

Avg. No. <strong>of</strong> Occupants<br />

No. <strong>of</strong> Spaces by Type<br />

120 asf<br />

n/a<br />

1 (Eastside); 1 (Westside)<br />

<strong>SA</strong>MPLE ROOM LAYOUT<br />

This diagram is included as a planning tool to ensure that the space<br />

will function as the users require within the assigned square feet. It is<br />

not intended to dictate the final design or configuration <strong>of</strong> the space.<br />

MECHANICAL / PLUMBING<br />

Temperature/Humidity<br />

Air Changes/Hour<br />

Hot Water (HW)<br />

Other<br />

Variable 68°f to 75°f @ 50%rh<br />

min. per Code<br />

Cold Water (CW)<br />

ELECTRICAL / COMMUNICATIONS<br />

Power 110v/20a/1-phase - See Note 5<br />

Dedicated Circuits X Stand-by Power<br />

Data See Notes 4 and 5<br />

Other See Note 6<br />

FURNISHINGS, FIXTURES & EQUIPMENT<br />

NOTES (CONTINUED)<br />

Counter w/Upper and Lower Cabinets (one wall) cfci 2. Provide vision lite in entry door <strong>for</strong> visual access from the<br />

(1) Standard Movable Table (24” x 48”) <strong>of</strong>oi<br />

building corridors or adjacent spaces. Entry door to space<br />

shall be provided with keyed lock.<br />

(1) Networked Printer and / or Copier <strong>of</strong>oi<br />

3. Provide sound attenuation in the walls to keep equipment<br />

Laminating Machine<br />

<strong>of</strong>oi noise in the room from distracting staff in adjacent workspaces.<br />

4. Provide (2) 2-port data outlets and (1) telephone outlet (min.)<br />

on two perimeter walls and at counter location. Building shall<br />

be equipped with wireless technology and infrastructure.<br />

*Note: <strong>The</strong>re shall be a minimum clear distance <strong>of</strong> 24” between<br />

5. Convenience duplex power outlets shall be provided along<br />

lower cabinet top surface and the underside <strong>of</strong> the upper<br />

the perimeter walls and at counter location at regular intervals,<br />

in accordance with Code. When locating power and<br />

cabinets. All upper cabinets shall be a minimum clear depth <strong>of</strong><br />

12” inside to allow <strong>for</strong> storing three ring binders. If millwork is<br />

data outlets, pay special attention to the possible location <strong>of</strong><br />

lockable all locks shall be keyed to the same master key.<br />

equipment and furniture.<br />

6. Verify type <strong>of</strong> power requirements <strong>for</strong> specific copy machine<br />

NOTES<br />

and equipment; a dedicated circuit and data port may be<br />

required <strong>for</strong> copier.<br />

1. Reference “Code and Standards” chapter <strong>for</strong> in<strong>for</strong>mation<br />

regarding additional design requirements <strong>of</strong> this space which<br />

7. Provide 50 to 55 fc <strong>for</strong> general illumination. Lighting shall have<br />

may not be listed here.<br />

motion sensors; controls shall be located in close proximity to<br />

the entry door. This space does not require natural light. If<br />

applicable, provide windows with blinds or shades to control<br />

natural light.<br />

An Architectural Space Program <strong>for</strong> the <strong>City</strong> <strong>of</strong> <strong>San</strong> <strong>Antonio</strong><br />

Facility <strong>Programming</strong> and Consulting<br />

<strong>Pre</strong>-K 4 <strong>SA</strong> Early Childhood Centers - East and Westside Centers Final - May 2013<br />

Page 4.20