Technical Requirements<br />

Instructional Space<br />

TECHNICAL REQUIREMENTS<br />

ARCHITECTURAL<br />

Floor<br />

Resilient Flooring<br />

Base<br />

Rubber<br />

Walls Masonry - See Note 7<br />

Ceiling<br />

Acoustical Tile System<br />

Lighting<br />

Fluorescent<br />

MECHANICAL / PLUMBING<br />

Temperature/Humidity<br />

Air Changes/Hour<br />

Hot Water (HW)<br />

Other<br />

Variable 68°f to 75°f @ 50%rh<br />

min. per Code<br />

Cold Water (CW)<br />

ELECTRICAL / COMMUNICATIONS<br />

Power 110v/20a/1-phase -See Note 12-14<br />

Dedicated Circuits<br />

Stand-by Power<br />

Data See Notes 11 , 12 and 14<br />

Other<br />

FURNISHINGS, FIXTURES & EQUIPMENT<br />

Industrial Metal Shelving<br />

Lockable Metal Storage Cabinets (48” x 20”)<br />

<strong>of</strong>oi<br />

<strong>of</strong>oi<br />

Note: Curriculum had not been developed at the time<br />

<strong>of</strong> publication <strong>of</strong> this report. Actual equipment storage<br />

requirements will be determined based on final curriculum.<br />

Gross motor skills involve movements using the large muscles<br />

<strong>of</strong> the body. <strong>The</strong>y include things like running, jumping,<br />

catching and throwing balls, and other large muscle activities.<br />

GROSS MOTOR SKILLS CLASSROOM (IS-02)<br />

Facility <strong>Programming</strong> and Consulting<br />

An Architectural Space Program <strong>for</strong> the <strong>City</strong> <strong>of</strong> <strong>San</strong> <strong>Antonio</strong><br />

Final - May 2013<br />

<strong>Pre</strong>-K 4 <strong>SA</strong> Early Childhood Centers - East and Westside Centers<br />

Page 4.11<br />

NOTES<br />

1. Reference “Code and Standards” chapter <strong>for</strong> in<strong>for</strong>mation<br />

regarding additional design requirements <strong>of</strong> this space<br />

which may not be listed here.<br />

2. Space should be centrally located near the General Classrooms.<br />

Direct access to the Outdoor Play Area from this<br />

space is also preferred. Consider alternate location <strong>of</strong> this<br />

space with visibility only (no access), via glass storefront,<br />

from the building Lobby/Reception Area.<br />

3. Floor area shall be clear and open and not be obstructed by<br />

building structural elements.<br />

4. Provide vision lite in entry door <strong>for</strong> visual access from the<br />

building corridors or adjacent spaces. Entry door to space<br />

shall be provided with keyed lock.<br />

5. Locate doors within space to minimize congestion. Consider<br />

the utilization <strong>of</strong> a Dutch door at the classroom entrance to<br />

allow <strong>for</strong> adults to converse while maintaining a secure environment<br />

<strong>for</strong> the children in the classroom.<br />

6. Provide windows from corridor into space to allow <strong>for</strong><br />

monitoring <strong>of</strong> classes in progress by parents, administrators<br />

or <strong>for</strong> pr<strong>of</strong>essional development training purposes.<br />

7. Utilize CMU wall or other approved masonry material.<br />

Apply glazed coating or heavy-duty epoxy to 12’-0” AFF<br />

(min.). Consider installation <strong>of</strong> acoustic panels above this<br />

point to assist in minimization <strong>of</strong> sound transmission. Wall<br />

and ceiling assemblies should minimize sound transmission.<br />

Reference “Code and Standards” chapter <strong>for</strong> recommended<br />

STC rating. Walls should be provided with fasteners or other<br />

mechanism <strong>for</strong> securing safety pads up to 6’-0” AFF to protect<br />

children from accidental impact. Coordinate type and<br />

location with User.<br />

8. Speech shall be intelligible without amplification.<br />

9. All lighting shall have motion sensors. Provide 50 to 55 footcandle<br />

(fc) <strong>for</strong> general illumination. All lighting fixtures shall<br />

be appropriately protected to withstand potential unintended<br />

impact by sports equipment.<br />

10. Lighting controls shall be located within close proximity to<br />

all entry doors. Zone lighting to allow <strong>for</strong> future flexibility if<br />

space is converted to General Classroom.<br />

11. Provide (1) 2-port data outlet (min.) at the proposed future<br />

teaching wall and at the opposite back wall. Building shall be<br />

equipped with wireless technology and infrastructure.<br />

12. Locate data and electrical outlet at ceiling <strong>for</strong> future projection<br />

equipment and at SmartBoard (where utilized). Coordinate<br />

outlet with future projector and SmartBoard locations.<br />

13. Convenience duplex power outlets shall be provided along<br />

the perimeter walls at regular intervals, in accordance with<br />

Code.<br />

14. When locating power and data outlets, special attention<br />

should be paid to the possible location <strong>of</strong> classroom equipment<br />

and furniture.<br />

15. Natural light into the space is desired. Windows shall be provided<br />

with blinds or shades to control natural light.