Technical Requirements<br />

Pr<strong>of</strong>essional Development Space<br />

TRAINING / MULTIPURPOSE ROOM (PD-01)<br />

TECHNICAL REQUIREMENTS<br />

ARCHITECTURAL<br />

Floor<br />

Base<br />

Walls<br />

Ceiling<br />

Lighting<br />

MECHANICAL / PLUMBING<br />

Temperature/Humidity<br />

Air Changes/Hour<br />

Hot Water (HW)<br />

Other<br />

Carpet Tile<br />

Rubber<br />

Painted Gypsum Wallboard<br />

Acoustical Tile System<br />

Fluorescent<br />

Variable 68°f to 75°f @ 50%rh<br />

min. per Code<br />

Cold Water (CW)<br />

ELECTRICAL / COMMUNICATIONS<br />

Power 110v/20a/1-phase - See Note 11, 12<br />

Dedicated Circuits<br />

Stand-by Power<br />

Data See Notes 10 thru 12<br />

Other<br />

FURNISHINGS, FIXTURES & EQUIPMENT<br />

(30) Standard Movable Tables (72” x 24”) <strong>of</strong>oi<br />

(60) Stackable Movable Chairs <strong>of</strong>oi<br />

(1) Movable Teaching Desk w/Movable Chair <strong>of</strong>oi<br />

(1) Lockable Media Cabinet <strong>of</strong>oi<br />

(2) Ceiling Mounted Projectors <strong>of</strong>ci<br />

(1) Document Camera <strong>of</strong>oi<br />

(1) DVD Player and/or VCR <strong>of</strong>oi<br />

Tackable Wall Surface - 8 Linear Feet (min.)<br />

cfci<br />

(1) Wall-Mounted Pencil Sharpener cfci<br />

Whiteboard AND / OR<br />

SmartBoard Surface - 16 Linear Feet (min.) cfci<br />

(1) Recessed Drop-Down Motorized Projection<br />

Screen - 72” wide (min.)<br />

cfci<br />

(1) Movable Partition Wall (betw. rooms) - See Note 3 cfci<br />

NOTES<br />

1. Reference “Code and Standards” chapter <strong>for</strong> in<strong>for</strong>mation<br />

regarding additional design requirements <strong>of</strong> this space which<br />

may not be listed here.<br />

NOTES (CONTINUED)<br />

2. This space should be located accessible from or adjacent to<br />

the main building entry Lobby / Reception Area to limit<br />

public accessibility to other parts <strong>of</strong> the building where children<br />

are located.<br />

3. Consideration should be given to the utilization <strong>of</strong> a movable<br />

partition wall between Training / Multipurpose Rooms<br />

to allow flexibility to increase class size <strong>for</strong> large events.<br />

4. Provide vision lite in entry door <strong>for</strong> visual access from the<br />

building corridors or adjacent spaces. Entry door to space<br />

shall be provided with keyed lock. Locate doors within<br />

space to minimize congestion and in a manner which will<br />

minimize disruption during lecture.<br />

5. Wall and ceiling assemblies should minimize sound transmission.<br />

Reference “Code and Standards” chapter <strong>for</strong> recommended<br />

STC rating. Speech within space shall be intelligible<br />

without amplification.<br />

6. View <strong>of</strong> the projection screen, whiteboard and / or teaching<br />

area shall not be obstructed by building structural elements.<br />

Projection screen should be located so as not to obstruct<br />

in<strong>for</strong>mation written on the whiteboards. Motorized projection<br />

screen may not be required if whiteboard surface is<br />

designed to also be utilized as a projection screen. Coordinate<br />

with User.<br />

7. All lighting shall have motion sensors. Provide 50 to 55 footcandle<br />

(fc) <strong>for</strong> general illumination; 20fc (min.) <strong>for</strong> note taking<br />

during projection.<br />

8. Lighting controls shall be located within close proximity to<br />

all entry doors. Controls shall also be either located within<br />

close proximity to or controlled from the teaching station.<br />

Zone in order to allow proper viewing <strong>of</strong> projected images<br />

and in a manner which allows <strong>for</strong> light fixtures at / near the<br />

projection screen to remain <strong>of</strong>f so as not to impede viewing<br />

<strong>of</strong> images on the screen.<br />

9. Classroom teaching equipment (document camera, DVD<br />

player, and computer) shall be placed in lockable media<br />

cabinet located near the teaching wall.<br />

10. Provide (1) 2-port data outlet (min.) at the teaching wall and<br />

at the opposite back wall. Building shall be equipped with<br />

wireless technology and infrastructure.<br />

11. Locate data and electrical outlet at ceiling <strong>for</strong> projection<br />

equipment and at SmartBoard (where utilized). Coordinate<br />

outlet with projector and SmartBoard locations.<br />

12. Convenience duplex power outlets shall be provided along<br />

the perimeter walls at regular intervals, in accordance<br />

with Code. When locating power and data outlets, special<br />

attention should be paid to the possible location <strong>of</strong> classroom<br />

equipment and furniture.<br />

13. Natural light into the space is desired. Windows shall be provided<br />

with blinds or shades to control natural light.<br />

Facility <strong>Programming</strong> and Consulting<br />

An Architectural Space Program <strong>for</strong> the <strong>City</strong> <strong>of</strong> <strong>San</strong> <strong>Antonio</strong><br />

Final - May 2013<br />

<strong>Pre</strong>-K 4 <strong>SA</strong> Early Childhood Centers - East and Westside Centers<br />

Page 4.29

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!