Installation ACE969TP-2 and ACE969FO-2<br />

Multi-protocol interfaces<br />

Description<br />

1 Grounding/earthing terminal using supplied braid<br />

2 Power-supply terminal block<br />

3 RJ45 socket to connect the interface to<br />

the base unit with a CCA612 cord<br />

4 Green LED: ACE969-2 energized<br />

5 Red LED: ACE969-2 interface status<br />

b LED off = ACE969-2 set up and communication<br />

operational<br />

b LED flashing = ACE969-2 not set up or setup<br />

incorrect<br />

b LED remains on = ACE969-2 has faulted<br />

6 Service connector: reserved for software upgrades<br />

7 E-LAN 2-wire RS 485 communication port<br />

(ACE969TP-2 and ACE969FO-2)<br />

8 S-LAN 2-wire RS 485 communication port<br />

(ACE969TP-2)<br />

9 S-LAN fiber-optic communication port<br />

(ACE969FO-2).<br />

1 Draw-out terminal block, with two rows of<br />

connections to the RS 485 2-wire network:<br />

b 2 black terminals: connection of RS 485 twistedpair<br />

(2 wires)<br />

b 2 green terminals: connection of twisted pair for<br />

distributed power supply<br />

2 Indication LEDs:<br />

b flashing Tx LED: Sepam sending<br />

b flashing Rx LED: Sepam receiving<br />

3 Jumper for RS 485 network line-end impedance<br />

matching with load resistor (Rc = 150 Ω), to be set<br />

to:<br />

b Rc,<br />

if the interface is not at the line end (default<br />

position)<br />

b Rc, if the interface is at the line end.<br />

1 Indication LEDs:<br />

b flashing Tx LED: Sepam sending<br />

b flashing Rx LED: Sepam receiving<br />

2 Rx, female ST-type connector (Sepam receiving)<br />

3 Tx, female ST-type connector (Sepam sending).<br />

PCRED301005EN - 06/<strong>20</strong>08<br />

DB114628<br />

DB114630<br />

DB114632<br />

ACE969-2 communication interfaces<br />

ACE969TP-2 ACE969FO-2<br />

S E N S DE LE C T U R E<br />

ACE969TP-2<br />

2<br />

2-wire RS 485 communication ports<br />

S-LAN port (ACE969TP-2) E-LAN port (ACE969TP-2 or<br />

ACE969FO-2)<br />

Fiber optic communication port<br />

S-LAN port (ACE969FO-2)<br />

1<br />

3 4 5 6<br />

Rx Tx on Rx Tx<br />

B A V- V+<br />

1 2 3 4 5<br />

S-LAN E-LAN<br />

1 2 3 4 5<br />

1 2 3 4 5<br />

1 8 7<br />

Rx Tx on Rx Tx<br />

B A V- V+<br />

1 2 3 4 5<br />

S-LAN E-LAN<br />

3<br />

2<br />

Rc<br />

Rc<br />

1 2 3 4 5<br />

1<br />

Rc<br />

Rc<br />

1 2 3 4 5<br />

Rx Tx on Rx Tx<br />

s<br />

B A V+<br />

1 2 3 4 5<br />

S-LAN E-LAN<br />

3<br />

2<br />

Rc<br />

Rc<br />

1 2 3 4 5<br />

DB114629<br />

DB114631<br />

SENS DE LECTURE<br />

ACE969FO-2<br />

2<br />

Rx Tx on Rx Tx<br />

B A V- V+<br />

1 2 3 4 5<br />

LAN E-LAN<br />

3<br />

Rc<br />

Rc<br />

1 2 3 4 5<br />

3 4 5 6<br />

Rx Tx on Rx Tx<br />

B A V- V+<br />

1 2 3 4 5<br />

S-LAN E-LAN<br />

1 2 3 4 5<br />

1 9 7<br />

2<br />

1<br />

s<br />

6/45<br />

6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!