5<br />

Modbus communication Presentation<br />

5/2<br />

General<br />

Modbus communication allows Sepam to be connected to a supervisor or any other<br />

device with a master Modbus communication channel.<br />

Sepam is always a slave station.<br />

Sepam is connected to a Modbus communication network via a communication<br />

interface.<br />

There is a choice of two types of communication interface:<br />

b communication interfaces to connect Sepam to a single network:<br />

v ACE949-2, for connection to a 2-wire RS 485 network<br />

v ACE959, for connection to a 4-wire RS 485 network<br />

v ACE937, for connection to a fiber-optic star network.<br />

b communication interfaces to connect Sepam to two networks:<br />

v ACE969TP-2, for connection to:<br />

- one 2-wire RS 485 Modbus S-LAN supervision communication network<br />

- one 2-wire RS 485 E-LAN engineering communication network.<br />

v ACE969FO-2, for connection to:<br />

- one fiber-optic Modbus S-LAN supervision communication network<br />

- one 2-wire RS 485 E-LAN engineering communication network.<br />

Data available<br />

The data available depend on the type of Sepam.<br />

Measurement readout<br />

b phase and earth fault currents<br />

b peak demand phase currents<br />

b tripping currents<br />

b cumulative breaking current<br />

b phase-to-phase, phase-to-neutral and residual voltages<br />

b frequency<br />

b temperatures<br />

b thermal capacity used<br />

b starts per hour and inhibit time<br />

b running hours counter<br />

b motor starting current and time<br />

b operating time before overload tripping<br />

b waiting time after tripping<br />

b operating time and number of operations<br />

b circuit breaker charging time.<br />

Program logic data readout<br />

b a table of 64 pre-assigned remote indications (TS) (depends on the type of<br />

Sepam) enables the readout of program logic data status<br />

b readout of the status of 10 logic inputs.<br />

Remote control orders<br />

Writing of 16 impulse-type remote control orders (TC) in either direct mode or SBO<br />

(Select Before Operate) mode via 16 selection bits.<br />

Other functions<br />

b reading of Sepam configuration and identification<br />

b time-tagging of events (synchronization via the network or externally via logic input<br />

I21), time-tagging within a millisecond<br />

b remote reading of Sepam settings<br />

b remote setting of protection units<br />

b remote control of the analog output (with MSA141 option)<br />

b transfer of disturbance recording data.<br />

PCRED301005EN - 06/<strong>20</strong>08