Scheduled Maintenance4.4. SPECIAL TOOLS AND TEST EQUIPMENTA list of the special tools and test equipment used in preventive maintenanceprocedures follows:1/4" Point-Detector Gauge• 1 Ammeter, 15A Min.• 1 Ammeter, 30-0-30 Amps DC• 1 No. 00 Sandpaper• 1 Multimeter• 1 Grease Gun with Spare Cartridge• 1 <strong>Switch</strong> Wrench 2"• 1 <strong>Switch</strong> Wrench 1 5/8"• 1 Hand Crank• 1 <strong>Switch</strong> Wrench 1 1/4"• Cotter Pins• 1 <strong>Switch</strong> Wrench 1 1/16"• 1 Rule/Tape Measure• 1 Terminal Nut Wrench, AAR or <strong>Alstom</strong>• Rags• 1 Wrench 3/8"• 1 Oil Can with Mobil Aero HFA or equivalent• 1 Wrench 3/4" and 7/8"• 1 Wrench 9/16"• 1 Force Gauge (pounds)• 1 Force Gauge (grams)All special tools required to facilitate maintenance are shown in Figure 7–18 located inSection 7, Parts Catalog.P1293, Rev. Jun/07 4–2 <strong>Alstom</strong> Signaling Inc.