13.07.2015 Views

Models 5E, 5F, 5G & 5H Electric Switch Machines: Single ... - Alstom

Models 5E, 5F, 5G & 5H Electric Switch Machines: Single ... - Alstom

Models 5E, 5F, 5G & 5H Electric Switch Machines: Single ... - Alstom

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Installation3.6.2.1. Changing Over the One Lock And One Point-Detector Rod, Right- OrLeft-Hand (RH Or LH) <strong>Single</strong> <strong>Switch</strong> ConfigurationTable 3–11. Changing Over Procedure For One Lock And One Point-Detector Rod,Right- Or Left-Hand (RH Or LH) <strong>Single</strong> <strong>Switch</strong>StepAction1 Remove lug with adjacent lock and adjusting nuts from solid-through lockrod.2 Remove two arms (clips) from top of lock rod.3 Crank machine to unlocked position.4 Pull lock rod as a unit out of one side of machine and insert it into machinefrom opposite side.5 Replace lug and lock and adjust nuts on solid-through lock rod.6 Replace arms (clips) on top of lock rod.7 Remove lug with adjacent lock and adjusting nuts from solid-through pointdetectorrod.P1293, Rev. Jun/07 3–23 <strong>Alstom</strong> Signaling Inc.