TroubleshootingTable 5–1. Symptoms Noticed from the Control Locations (Cont.)Symptom8) <strong>Switch</strong> flashing out ofcorrespondence, RWC or NWC relaydown (per switch position request).Corrective Action1) Check that RWP or NWP relay is up.2) Check for 12V DC at relay.3) Check for loose hardware andconnections.4) Check for faulty relay.P1293, Rev. Jun/07 5–3 <strong>Alstom</strong> Signaling Inc.